Home › Fuel System › Engine Control System

P0079 Exhaust Valve Control Solenoid Circuit Low (Bank 1)

Component Location

General Description
The CVVT (Continuously Variable Valve Timing) system built on the camshaft helps the engine decrease the exhaust gas and increase engine power and fuel economy by changing the valve open/close timing of the camshaft continuously. The valve control solenoid, the main control part of the CVVT, changes the direction of the oil path through the CVVT by the duty control of the PCM and changes the open and close timing of the intake and exhaust valves.
DTC Description
PCM sets DTC P0079 if the PCM detects that the exhaust valve control solenoid control circuit is short to ground.
DTC Detecting Condition
Item
Detecting Condition
Possible Cause
DTC Strategy
•
Electrical Check
•
Short to ground in control circuit
•
Poor connection or damaged harness
•
Faulty Exhaust Valve Control Solenoid
Enable Conditions
•
10V < Battery voltage < 16V
Threshold Value
•
Short circuit to ground or open circuit
Diagnostic Time
•
2sec.
Mil On Condition
•
-

Specification
Oil Control Valve
Normal Parameter At 20°C (68°F)
Insulation Resistance
Above 50 MΩ

Temp.(°C)
Temp.(°F)
Resistance(Ω)
Temp.(°C)
Temp.(°F)
Resistance(Ω)
0
32
6.2 ~ 7.4
60
140
8.0 ~ 9.2
10
50
6.5 ~ 7.7
70
158
8.3 ~ 9.5
20
68
6.9 ~ 7.9
80
176
8.6 ~ 9.8
30
86
7.1 ~ 8.3
90
194
8.9 ~ 10.1
40
104
7.4 ~ 8.6
100
212
9.2 ~ 10.4
50
122
7.7 ~ 8.9




Diagnostic Circuit Diagram

Signal Waveform & Data

Engine Speed (RPM)
Inlet Camshaft Position Control
Exhaust Camshaft Position Control
Monitor DTC Status
1.
Connect GDS and select "DTC Analysis" mode
2.
Click "DTC Status" on the menu bar to see DTC's information.
3.
Confirm that "DTC Readiness Flag" indicates "COMPLETED". If not, drive the vehicle within conditions noted in the freeze frame data or enable conditions.
4.
Read "DTC Status" parameter.

5.
Is parameter displayed "History(Not Present) fault"?
- History (Not Present) fault : DTC occurred but has been cleared.
- Present fault : DTC is occurring at present time.

▶ Fault is intermittent caused by poor contact in the sensor's and/or PCM's connector or was repaired and PCM memory was not cleared. Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage. Repair or replace as necessary and then go to "Verification of Vehicle Repair" procedure.

▶ Go to next step as below

Component Inspection
1.
Ignition "OFF"
2.
Disconnect oil control valve connector
3.
Measure resistance between power terminal and control terminal of the solenoid connector(Component side).
Specification
Temp.(°C)
Temp.(°F)
Resistance(Ω)
0
32
6.2 ~ 7.4
10
50
6.5 ~ 7.7
20
68
6.9 ~ 7.9
30
86
7.1 ~ 8.3
40
104
7.4 ~ 8.6
50
122
7.7 ~ 8.9
60
140
8.0 ~ 9.2
70
158
8.3 ~ 9.5
80
176
8.6 ~ 9.8
90
194
8.9 ~ 10.1
100
212
9.2 ~ 10.4

4.
Is resistance within specification?

▶ Go to next step as below

▶ Check oil control valve for contamination, deterioration, or damage. Substitute with a known-good solenoid and check for proper operation. If the problem is corrected, replace solenoid and then go to "Verification of Vehicle Repair" procedure

Power Circuit Inspection
1.
Ignition "ON" & Engine "OFF"
2.
Measure voltage between power terminal of the oil control valve harness connector and chassis ground.

Specification : Approx. B+

3.
Is voltage within specification?

▶ Go to "Control Circuit Inspection" procedure.

▶ Repair open or short to ground in the power supply circuit and go to "Verification of Vehicle Repair" procedure

Control circuit inspection
1.
Measure voltage between control terminal of the oil control valve harness connector and chassis ground.

Specification : Approx. 3~4V

Signal waveform in control circuit with ignition ON & Engine OFF
2.
Is voltage within specification?

▶ Go to "Terminal and Connector Inspection" procedure.

▶ Repair short to ground in control circuit and go to "Verification of Vehicle Repair" procedure.

Terminal and Connector Inspection
1.
Many malfunctions in the electrical system are caused by poor harness(es) and terminals. Faults can also be caused by interference from other electrical systems, and mechanical or chemical damage.
2.
Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage.
3.
Has a problem been found?

▶ Repair as necessary and go to "Verification of Vehicle Repair" procedure

▶ Check for poor connection between PCM and component: backed out terminal, improper mating, broken locks or poor terminal to wire connection. Repair as necessary and go to "Verification of Vehicle Repair" procedure

Verification of Vehicle Repair
After a repair, it is essential to verify that the fault has been corrected.
1.
Connect GDS and select "DTC Analysis" mode.
2.
Click "DTC Status" and confirm that "DTC Readiness Flag" indicates "Complete". If not, drive the vehicle within conditions noted in the freeze frame data or enable conditions.
3.
Read "DTC Status" parameter.
4.
Is parameter displayed "History(Not Present) fault"?

▶ System performing to specification at this time. Clear the DTC.

▶ Go to the applicable troubleshooting procedure.