Power Relay Test (Type A)
Check for continuity
between the terminals.
| 1. |
There should be continuity between the No.1
and No.2 terminals when power and ground are connected to the No.3
and No.4 terminals. |
| 2. |
There should be no continuity between the No.1
and No.2 terminals when power is disconnected.
A : A/T relay
B : Fuel pump relay
C : Air conditioning relay
D : Front fog relay
E : Horn relay


|
Power Relay Test (Type B)
Check for continuity
between the terminals.
| 1. |
There should be continuity between the No.1
and No.2 terminals when power and ground are connected to the No.3
and No.5 terminals. |
| 2. |
There should be continuity between the No.1
and No.4 terminals when power is disconnected.
A : Wiper relay


|
Power Relay Test (Type C)
Check for continuity
between the terminals.
| 1. |
There should be continuity between the No.1
and No.4 terminals when power and ground are connected to the No.2
and No.3 terminals. |
| 2. |
There should be no continuity between the No.1
and No.4 terminals when power is disconnected.
A : Head lamp relay(Low)
B : Head lamp relay(High)
C : Start relay


|
Power Relay Test (Type D)
Check for continuity
between the terminals.
| 1. |
There should be continuity between the No.1
and No.4 terminals when power and ground are connected to the No.2
and No.3 terminals. |
| 2. |
There should be continuity between the No.1
and No.5 terminals when power is disconnected.
A : E/G control (Main relay)


|
Fuse Inspection
| 1. |
Be sure there is no play in the fuse holders,
and that the fuses are held
securely. |
| 2. |
Are the fuse capacities for each circuit
correct? |
| 3. |
Are there any blown fuses?
If a fuse is to be replaced, be sure to use a
new fuse of the same capacity. Always determine why the fuse blew
first and completely eliminate the problem before installing a new
fuse. |