Home › Heating,Ventilation, Air Conditioning › Heater › Mode Control Actuator

Heater › Mode Control Actuator: Repair procedures

Inspection
1.
Ignition "OFF”.
2.
Disconnect the connector of mode control actuator.
3.
Verify that the mode control actuator operates to the defrost position when connecting 12V to the terminal 3 and grounding terminal 4.
4.
Verify that the mode control actuator operates to the vent position when connecting in the reverse.

5.
Check the voltage between terminals 5 and 6.
Door position
Voltage (5-6)
Error detecting
Vent
0.3 ± 0.15V
Low voltage : 0.1V or less
Defrost
4.7 ± 0.15V
High voltage : 4.9V or more

It will feedback current position of actuator to controls.
6.
If the measured voltage is not specification, substitute with a known-good mode control actuator and check for proper operation.
7.
If the problem is corrected, replace the mode control actuator.
Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Pull out the driver’s crush pad center lower cover (A).

3.
Disconnect the connector of mode control actuator after removing the air duct.
4.
Loosen the mounting screws and then remove the mode control actuator (B).

5.
Install in the reverse order of removal.