Variable Foced Solenoid
(Linear Solenoid) : With the duty control which uses higher
frequency(600Hz), instead of the existing PWM type which adapts low
frequency(60Hz) to control,spool valve can be conrolled
precisely.
n PWM control,the amount
of oil flow is determined by the duration of "ON"signal among continuously
repeated ON/OFF signals.
In VFS, the amount is
decided by how widely spool valve open the passage of going
through.
The TCM checks the VFS
Control Signal by monitoring the feedback signal from the solenoid valve
drive circuit. If an unexpected signal is monitored (for example, high
voltage is detected when low voltage is expected, or low voltage is
detected when high voltage is expected), the TCM judges that the Low and
Reverse control solenoid circuit is malfunctioning and sets this code.
Item
|
Detecting
Condition
|
Possible Cause
|
DTC
Strategy
|
|
| •
|
Open or short in
circuit |
| •
|
Faulty LR SOLENOID
VALVE |
|
Enable
Conditions
|
|
Threshold
Value
|
| •
|
Current operating state of
VFS | |
Diagnostic
Time
|
|
Fail
Safe
|
|
Solenoid Valve for
Pressure Control
| - |
Sensor type : Normal open
3-way |
| - |
Operating temperature :
-22~266°F(-30°C~130°C) |
| - |
Frequency : LR, 2ND, UD, OD, RED : 61.27Hz (at
the ATF temp. -20°C above)
DCC : 30.64Hz
※ KM series :
35Hz |
| - |
Internal resistance : 2.7~3.4Ω(68°F or
20°C) |

Fig 1) Wave form of
"VFS"
| 1. |
Connect scantool to data link
connector(DLC) |
| 3. |
Monitor the "PRESS CONTROL SOL. VALVE"
parameter on the scantool |
| 4. |
Shift gear position "N" to "4TH
GEAR".
_11.gif)
_12.gif)
_13.gif)
_14.gif)
FIG 1) P,N
FIG 2) "R"
FIG 3) "D 1st" gear
FIG 4) "2nd" gear
FIG 5) "3rd" gear
FIG 6) "4th" gear
FIG 7) "5th"
gear |
| 5. |
Does "PRESS CONTROL SOL DUTY" follow the
referance data?
|

|
▶ Fault is
intermittent caused by poor contact in the sensor's and/or
TCM(PCM)'s connector or was repaired and TCM(PCM) memory was
not cleared. Throughly check connectors for looseness, poor
connection, bending, corrosion, contamination, deterioration
or damage.Repair or replace as necessary and go to
"Verification Vehicle Repair" procedure.
|
|

|
▶ Go to
"W/Harness Inspection"
procedure.
|
|
| Terminal and Connector
Inspection |
| 1. |
Many malfunctions in the electrical system are
caused by poor harness and terminals. Faults can also be caused by
interference from other electrical systems, and mechanical or
chemical damage. |
| 2. |
Thoroughly check connectors for looseness,
poor connection, bending, corrosion, contamination, deterioration,
or damage. |
| 3. |
Has a problem been found?
|

|
▶ Repair as
necessary and go to "Verification vehicle Repair"
procedure
|
|

|
▶ Go to
"Power Circuit Inspection" procedure
|
|
| 1. |
Disconnect "A/T SOLENOID VALVE"
connector. |
| 2. |
Measure voltage between teminal"8" of the
sensor harness connector and chassis
ground. |
| 3. |
Measure voltage of VFS solenoide
valve
Specification: 12V is
measured only for approx. 0.5sec
|

|
| 4. |
Is voltage within specifications?
|

|
▶ Go to
"Signal Circuit Inspection" procedure
|
|

|
▶ Check
that A/T-20A Fuse in engine room junction is installed or not
blown. ▶ Check for open in
harness. Repair as necessary and Go to "Verification Vehicle
Repair"
procedure
|
|
| Signal Circuit
Inspection |
| Check Signal Circuit
Open Inspection |
| 2. |
Disconnect "A/T SOLENOID VALVE" connector and
"PCM/TCM" connector |
| 3. |
Measure resistance between terminal "7" of the
ATM SOLENOID VALVE harness connector and terminal "75" of the TCM
harness connector
Specification: Approx. 0
Ω
|

|
| 4. |
Is resistance within
specifications?
|

|
▶ Go to
"Check signal circuit short Inspection" procedure
|
|

|
▶ Check for
open in harness. Repair as necessary and Go to "Verification
Vehicle Repair"
procedure
|
|
| Check Signal Circuit
Short Inspection |
| 2. |
Disconnect "A/T SOLENOID VALVE" connector and
"PCM/TCM" connector |
| 3. |
Measure resistance between terminal "7" of the
ATM SOLENOID VALVE harness and chassis ground.

|
| 4. |
Is resistance within
specifications?
|

|
▶ Go to
"Component Inspection" procedure
|
|

|
▶ Check for
short to ground in harness. Repair as necessary and Go to
"Verification Vehicle Repair"
procedure
|
|
| 2. |
Disconnect "A/T SOLENOID VALVE" connector
|
| 3. |
Measure resistance between terminal "7" and
terminal "8" of the ATM SOLENOID VALVE harness
connector
Specification
: Approximately 4.35 ± 0.35 Ω
(20°C)
|

|
| 4. |
Is resistance within
specifications?
|

|
▶ Go to
"CHECK PCM/TCM " as below
|
|

|
▶ Replace
"PRESS CONTROL SOL VALVE(VFS)" as necessary and go to
"Verification Vehicle Repair"
procedure
|
|
| 1. |
Connect scantool to data link
connector(DLC) |
| 2. |
Ignition "ON" & Engine
"OFF". |
| 3. |
Select A/T Solenoide valve Actuator test and
Operate Actuator test. |
| 4. |
Can you hear operating sound for "PRESS
CONTROL SOL VALVE(VFS)" Actuator Testing Function?
|

|
▶ Go to
"Verification Vehicle Repair" procedure
|
|

|
▶ Replace
PCM/TCM as necessary and Go to "Verificaiton Vehicle Repair"
procedure
|
ACTUATOR TEST CONDITION
1. IG SWITCH ON
2. TRANSAXLE RANGE SWITCH is normal
3. P RANGE
4. Vehicle Speed 0km/h
5. Throttle position sensor<
1V
6. IDLE SWITCH ON
7. ENGINE RPM
0 |
| Verification of Vehicle
Repair |
After a repair, it is
essential to verify that the fault has been corrected.
| 1. |
Connect scan tool and select "Diagnostic
Trouble Codes(DTCs)" mode. |
| 2. |
Using a scantool, Clear
DTC. |
| 3. |
Operate the vehicle within DTC Enable
conditions in General information. |
| 4. |
Are any DTCs present ?
|

|
▶ Go to the
applicable troubleshooting procedure.
|
|

|
▶ System
performing to specification at this
time.
|
|