The automatic TRANSAXLE
fluid(ATF) temperature sensor is installed in the Valve Body. This sensor
uses a thermistor whose resistance changes according to the temperature
changes. The TCM supplies a 5V reference voltage to the sensor, and the
output voltage of the sensor changes when the ATF temperature varies. The
automatic TRANSAXLE fluid(ATF) temperature provides very important data
for the TCM's control of the Torque Converter Clutch, and is also used for
many other purposes.
This DTC code is set
when the ATF temperature output voltage is lower than a value generated by
thermistor resistance, in a normal operating range, for approximately 1
second or longer. The TCM regards the ATF temperature as fixed at a value
of 80 °C.
Item
|
Detecting
Condition
|
Possible Cause
|
DTC
Strategy
|
| •
|
Check for Voltage range
| |
| •
|
Sensor signal circuit is short to
ground. |
|
Enable
Conditions
|
|
Threshold
Value
|
|
Diagnostic
Time
|
|
Fail
Safe
|
| •
|
Learning control and Intelligent shift
are inhibited |
| •
|
Fluid temperature is regarded as
80°C | |
TEMP.(°C)
|
RESISTANCE(kΩ)
|
TEMP.(°C)
|
RESISTANCE(kΩ)
|
40(40°F)
|
139.5
|
80(176°F)
|
1.08
|
20(4°F)
|
47.7
|
100(212°F)
|
0.63
|
0(32°F)
|
18.6
|
120(248°F)
|
0.38
|
20(68°F)
|
8.1
|
140(284°F)
|
0.25
|
40(104°F)
|
3.8
|
160(320°F)
|
0.16
|
60(140°F)
|
1.98
|
|
| 1. |
Connect scantool to data link
connector(DLC) |
| 3. |
Monitor the "TRANSAXLE FLUID TEMPERATURE
SENSOR" parameter on the scantool
Specification
: Increasing Gradually
|


Fig 1) Normal
Fig 2) Signal harness Open
Fig 3) Signal harness
Sho |
| 4. |
Does "TRANSAXLE FLUID TEMPERATURE SENSOR "
follow the referance data?
|

|
▶ Fault is
intermittent caused by poor contact in the sensor's and/or
TCM(PCM)'s connector or was repaired and TCM(PCM) memory was
not cleared. Throughly check connectors for looseness, poor
connection, bending, corrosion, contamination, deterioration
or damage.Repair or replace as necessary and go to
"Verification Vehicle Repair" procedure.
|
|

|
▶ Go to
"W/Harness Inspection"
procedure.
|
|
| Terminal and Connector
Inspection |
| 1. |
Many malfunctions in the electrical system are
caused by poor harness and terminals. Faults can also be caused by
interference from other electrical systems, and mechanical or
chemical damage. |
| 2. |
Thoroughly check connectors for looseness,
poor connection, bending, corrosion, contamination, deterioration,
or damage. |
| 3. |
Has a problem been found?
|

|
▶ Repair as
necessary and go to "Verification vehicle Repair"
procedure
|
|

|
▶ Go to
"Signal Circuit Inspection"
procedure
|
|
| Signal Circuit
Inspection |
| 1. |
Ignition "ON" & Engine
"OFF". |
| 2. |
Disconnect the "TRANSAXLE FLUID TEMPERATURE
SENSOR" connector |
| 3. |
Measure the voltage between terminal "1" of
the "TRANSMISSION FLUID TEMPERATURE SENSOR" harness connector and
chassis ground.
Specification
: Approx. 5 V
|

|
| 4. |
Is voltage within specifications
?
|

|
▶ Go to
"Component Inspection" procedure
|
|

|
▶ Check for
short to ground in harness. Repair as necessary and Go to
"Verification Vehicle Repair" procedure
|
|
| ■ Check "TRANSAXLE
FLUID TEMPERATURE SENSOR" |
| 2. |
Disconnect the "TRANSAXLE FLUID TEMPERATURE
SENSOR" connector |
| 3. |
Measure the resistance between terminals "1"
and "2" of the "TRANSMISSION FLUID TEMPERATURE SENSOR".
Specification
: Refer to " Reference
data"
|

[Reference data]
TEMP.(°C)
|
RESISTANCE(kΩ)
|
TEMP.(°C)
|
RESISTANCE(kΩ)
|
40(40°F)
|
139.5
|
80(176°F)
|
1.08
|
20(4°F)
|
47.7
|
100(212°F)
|
0.63
|
0(32°F)
|
18.6
|
120(248°F)
|
0.38
|
20(68°F)
|
8.1
|
140(284°F)
|
0.25
|
40(104°F)
|
3.8
|
160(320°F)
|
0.16
|
60(140°F)
|
1.98
|
|
|
| 4. |
Is resistance within
specifications?
|

|
▶ Go to
"CHECK PCM/TCM " as below
|
|

|
▶ Replace
"TRANSAXLE FLUID TEMPERATURE SENSOR" as necessary and Go to
"Verification Vehicle Repair" procedure.
|
|
| 1. |
Ignition "ON" & Engine
"OFF". |
| 2. |
Connect "TRANSAXLE FLUID TEMPERATURE SENSOR"
connector. |
| 3. |
Install scantool and slect a
SIMU-SCAN, |
| 4. |
Simulate voltage (0→5V) to "TRANSMISSION FLUID
TEMPERATURE SENSOR" signal circuit.

Fig 1) INPUT 1.00V → 165°F
Fig 2) INPUT 2.00V → 114°F
※ The values are subject to change according
to vehicle model or conditions. |
| 5. |
Is FLUID TEMP. SENSOR signal value changed
according to simulation voltage?
|

|
▶
Thoroughly check connectors for looseness, poor connection,
bending, corrosion, contamination, deterioration, or damage.
Repair or replace as necessary and then go to "Verification of
Vehicle Repair" procedure.
|
|

|
▶
Substitute with a known-good PCM/TCM and check for proper
operation. If the problem is corrected, replace PCM/TCM as
necessary and then go to "Verification of Vehicle Repair"
procedure.
|
|
| Verification of Vehicle
Repair |
After a repair, it is
essential to verify that the fault has been corrected.
| 1. |
Connect scan tool and select "Diagnostic
Trouble Codes(DTCs)" mode. |
| 2. |
Using a scantool, Clear
DTC. |
| 3. |
Operate the vehicle within DTC Enable
conditions in General information. |
| 4. |
Are any DTCs present ?
|

|
▶ Go to the
applicable troubleshooting procedure.
|
|

|
▶ System
performing to specification at this
time.
|
|