Home › Engine Mechanical System › Intake And Exhaust System › Muffler

Intake And Exhaust System › Muffler: Repair procedures

Removal
1.
Disconnect the oxygen sensor connector (A) and then remove the front muffler (B).


Tightening torque:
39.2 ~ 58.8 N.m (4.0 ~ 6.0 kgf.m, 28.9 ~ 43.4 lb-ft)

2.
Remove the catalytic converter (A) and the center muffler (B).

Tightening torque:
39.2 ~ 58.8 N.m (4.0 ~ 6.0 kgf.m, 28.9 ~ 43.4 lb-ft)

3.
Remove the main muffler (A).

Tightening torque:
39.2 ~ 58.8 N.m (4.0 ~ 6.0 kgf.m, 28.9 ~ 43.4 lb-ft)