Home › Fuel System › Engine Control System › Purge Control Solenoid Valve (PCSV)

Engine Control System › Purge Control Solenoid Valve (PCSV): Repair procedures

Inspection
1.
Turn the ignition switch OFF.
2.
Disconnect the PCSV connector.
3.
Measure resistance between the PCSV terminals 1 and 2.
4.
Check that the resistance is within the specification.

Specification: Refer to “Specification”

Removal
1.
Turn the ignition switch OFF and disconnect the battery negative (-) cable.
2.
Disconnect the purge control solenoid valve connector (A).
3.
Disconnect the vapor hoses (B) from the purge control solenoid valve.
4.
Remove the valve after removing the bolt (C).

Installation
•
Install the component with the specified torques.
•
Note that internal damage may occur when the component is dropped. If the component has been dropped, inspect before installing.
•
Use care to keep foreign material out of the valve.
1.
Installation is reverse of removal.

Purge control solenoid valve bracket installation bolt: 9.8 ~ 11.8 N.m (1.0 ~ 1.2 kgf.m, 7.2 ~ 8.7 lb-ft)