Home › Body Electrical System › Lighting System › Hazard Lamp Switch

Lighting System › Hazard Lamp Switch: Repair procedures

Inspection
Hazard Lamp Switch
1.
Disconnect the negative (-) battery terminal.
2.
Remove the air vent panel (A).
(Refer to the Body group - Crash pad)

3.
Disconnect the connectors.
4.
Operate the switch and check for continuity between terminals with an ohmmeter.