2007 Commander XK Factory Service Manual 8 - ELECTRICAL

B2113-5 VOLT SUPPLY CIRCUIT HIGH (FCM)





For a complete wiring diagram Refer to Section 8W.



Possible Causes
 
(F891) 5 VOLT SUPPLY CIRCUIT SHORTED TO VOLTAGE
 
A/C PRESSURE TRANSDUCER
 
FRONT CONTROL MODULE
 




Diagnostic Test

1. CHECK FOR ACTIVE DTC

With the scan tool, read the active DTC's.
Cycle the ignition switch from off to on, leaving the ignition on for a minimum of 90 seconds.
With the scan tool, read the active DTC's.

Does the scan tool display this DTC as active?

Yes


No

2. A/C PRESSURE TRANSDUCER

Turn the ignition off.
Disconnect the A/C Pressure Transducer harness connector.
Cycle the ignition switch from off to on, leaving the ignition on for a minimum of 90 seconds.
With the scan tool, read the active DTC's.

Does the scan tool display this DTC as active?

Yes


No

3. (F891) 5 VOLT SUPPLY CIRCUIT SHORTED TO VOLTAGE



Turn the ignition off.
Disconnect the FCM C1 harness connector.
Turn the ignition on.
Measure the voltage of the (F891) 5 Volt Supply circuit.

Is the voltage above 5.5 volts?

Yes


No