2007 Commander XK Factory Service Manual 8 - ELECTRICAL

B210D-BATTERY VOLTAGE LOW





For a complete wiring diagram Refer to Section 8W.



POSSIBLE CAUSES
 
LOW BATTERY VOLTAGE
 
CHARGING SYSTEM FAILURE
 
(A115) FUSED B(+) OR (Z125) GROUND CIRCUIT OPEN OR HIGH RESISTANCE
 
POWER LIFTGATE MODULE
 




Diagnostic Test

1. CHECK ENGINE DTC's

NOTE: Ensure the battery is fully charged before proceeding.


With the scan tool, read ENGINE DTC's

Are there any BATTERY OR CHARGING SYSTEM DTC's?

No


Yes

2. TEST FOR INTERMITTENT CONDITION

With the scan tool, record and erase DTC's
Start the engine and run for 2 minutes.
With the scan tool, read DTC's.

Does the scan tool display B210D-BATTERY VOLTAGE LOW?

Yes


No

3. CHECK THE (A115) FUSED B(+) AND THE (Z125) GROUND CIRCUITS FOR AN OPEN OR HIGH RESISTANCE



Disconnect the Power Liftgate Module C3 harness connector
Test for an open or high resistance on the (A115) Fused B(+) circuit by connecting a 12-volt test light between the (A115) Fused B(+) circuit and the (Z125) Ground circuit in the Power Liftgate Module harness C3 harness connector. The test light must illuminate brightly. Compare the brightness to that of a direct connection to the battery.

Does the test light illuminate brightly?

Yes


No