LAMP-LICENSE
8W-13 INTEGRATED POWER MODULE
Wiring diagrams
Connector — LAMP-LICENSE
4 way · (BASE)
| Cavity | Description | Circuit |
|---|---|---|
| 1 | FUSED PARK LAMP RELAY OUTPUT | L777 20WT/VT |
| 2 | GROUND | Z800 20BK |
| 3 | FLIP-UP GLASS SWITCH SENSE | Q80 20OR/VT |
| 4 | - | - |
Connector — LAMP-LICENSE
10 way · (EXCEPT BASE)
| Cavity | Description | Circuit |
|---|---|---|
| 1 | FUSED PARK LAMP RELAY OUTPUT | L777 20WT/VT |
| 2 | GROUND | Z800 20BK |
| 3 | FLIP-UP GLASS SWITCH SENSE | Q80 20OR/VT |
| 4 | - | - |
| 5 | LIFTGATE CHIME DRIVER | Q94 20TN/LG |
| 6 | CAMERA RETURN | X971 20DG/OR |
| 7 | CAMERA SIGNAL | X970 20DG/BR |
| 8 | CAMERA SHIELD | X972 20DG/WT |
| 9 | - | - |
| 10 | BACKUP LAMP FEED | L1 16WT/LG |