HORN RELAY
REMOVAL

1. Disconnect and isolate the battery negative cable.
2. Remove cover from Totally Integrated Power Module (TIPM).
3. Using special tool C-4817 (1), grip the relay (2) by the sides and pull upward with an even effort.
INSTALLATION

1. Align relay (2) with Totally Integrated Power Module (TIPM) and press into position.
2. Install cover to TIPM.
3. Connect battery negative cable.