2007 Compass Patriot MK Factory Service Manual 24 - HEATING & AIR CONDITIONING

B10EC-BLOWER MOTOR CONTROL CIRCUIT OVERCURRENT (TIPM)





For a complete wiring diagram Refer to Section 8W



Possible Causes
 
BLOCKAGE STALLING BLOWER MOTOR
 
BLOWER MOTOR
 
TOTALLY INTEGRATED POWER MODULE (TIPM)
 




Diagnostic Test

1. VERIFY DTC B10EC-BLOWER MOTOR CONTROL CIRCUIT OVERCURRENT IS ACTIVE

Turn the ignition on.
With the scan tool, erase DTCs.
Turn the ignition off, wait 10 seconds, and turn the ignition on.
With the scan tool, read DTCs.

Does the scan tool display active: B10EC-BLOWER MOTOR CONTROL CIRCUIT OVERCURRENT?

Yes


No

2. CHECK FOR PROPER BLOWER MOTOR OPERATION

Turn the ignition on.
Turn the Blower Motor on.

Does the Blower Motor operate normally?

Yes


No

3. CHECK FOR ACTIVE: B10E9–BLOWER MOTOR CONTROL CIRCUIT LOW

Turn the ignition on.
With the scan tool, erase DTCs.
Turn the ignition off, wait 10 seconds, and turn the ignition on.
Turn on the Blower Motor.
With the scan tool, read DTCs.

Does the scan tool display active: B10E9–BLOWER MOTOR CONTROL CIRCUIT LOW?

Yes


No

4. CHECK FOR 12 VOLTS TO THE BLOWER MOTOR



Turn the ignition off.
Disconnect the Blower Motor harness connector.
Turn the ignition on.
Turn the Blower Motor control on.
Using a volt meter measure the voltage on the (C7) Blower Motor Control circuit in the Blower Motor harness connector.

Does the volt meter read 12 volts?

Yes


No

5. CHECK FOR A BLOCKAGE STALLING THE BLOWER MOTOR

Turn the ignition off.
Remove the Blower Motor from the HVAC housing assembly.
Look for anything on the Blower Motor and in the HVAC housing that is physically preventing Blower Motor operation.

Is anything physically preventing Blower Motor operation?

Yes


No

6. CHECK FOR CHAFING IN THE (C7) BLOWER MOTOR CONTROL CIRCUIT

Turn the ignition off.
Check the (C7) Blower Motor Control circuit for wire chafing.

Is any wire chafing present?

Yes


No