2007 Grand Cherokee WK Factory Service Manual 9 - ENGINE

P0691-COOLING FAN 1 RELAY CONTROL CIRCUIT LOW





For a complete wiring diagram Refer to Section 8W.



Possible Causes
 
(A16) FUSED B+ CIRCUIT
 
(N201) LOW SPEED FAN RELAY CONTROL CIRCUIT OPEN
 
(N201) LOW SPEED FAN RELAY CONTROL CIRCUIT SHORTED TO GROUND
 
LOW SPEED RADIATOR FAN RELAY
 
FCM
 


Always perform the Pre-Diagnostic Troubleshooting procedure before proceeding. (Refer to 9 - ENGINE - DIAGNOSIS AND TESTING).



Diagnostic Test

1. LOW SPEED RADIATOR FAN RELAY OPERATION

Ignition on, engine not running.
With a scan tool, actuate the Low Speed Radiator Fan Relay.

Is the Cooling Fan Relay operating?

Yes


No

2. INTERNAL FUSED B+ CIRCUITS



Turn the ignition off.
Remove the Low Speed Radiator Fan Relay.
Using a 12-volt test light connected to ground, probe the Internal Fused B+ circuits.

Is the voltage above 11.0 volts?

Yes


No

3. LOW SPEED RADIATOR FAN RELAY RESISTANCE

Measure the resistance of the Low Speed Radiator Fan Relay Coil.

Is the resistance between 60 to 80 ohms?

Yes


No

4. (N201) COOLING FAN NO.1 CONTROL CIRCUIT OPEN



Disconnect the IPM FCM 49 way harness connector.
Measure the resistance of the (N201) Cooling Fan No.1 Relay Control circuit from the Relay to the IPM FCM harness connector.

Is the resistance below 5.0 ohms?

Yes


No

5. (N201) COOLING FAN NO.1 CONTROL CIRCUIT SHORTED TO GROUND



Measure the resistance between ground and the (N201) Cooling Fan No.1 Relay Control circuit at the Relay connection.

Is the resistance below 100 ohms?

Yes


No

6. FRONT CONTROL MODULE

NOTE: Before continuing, check the FCM harness connector terminals for corrosion, damage, or terminal push out. Repair as necessary.


Using the schematics as a guide, inspect the wire harness and connectors. Pay particular attention to all Power and Ground circuits.

Were there any problems found?

Yes


No