2007 Grand Cherokee WK Factory Service Manual 24 - HEATING & AIR CONDITIONING

B10A1-PANEL MODE DOOR 2 ACTUATOR PERFORMANCE (ATC)

For a complete wiring diagram Refer to Section 8W.

Theory of Operation


The A/C Heater Control monitors the door driver circuits during actuator operation for conditions that prevent proper door operation. If a pulse count error is detected the A/C Heater Control reports the fault as a Actuator Performance DTC. It is important to note that this DTC only indicates that a fault occurred while driving a door actuator and that additional testing is necessary to provide more details about the reported fault.



Possible Causes
 
DOOR DRIVER CIRCUIT(S) SHORTED HIGH, SHORTED LOW, SHORTED TOGETHER, OPEN
 
DOOR ACTUATOR(S) BINDING, BROKEN
 
DOOR ACTUATOR(S) LINKAGE BINDING, DISCONNECTED, MISSING, BROKEN
 
A/C HEATER CONTROL
 




Diagnostic Test

1. CHECK FOR ACTIVE CONTROL CIRCUIT/PERFORMANCE & CONTROL CIRCUIT OPEN DTCs

Turn the ignition on.
With the scan tool, read active HVAC DTCs.

Does the scan tool display any active: XXXX CONTROL CIRCUIT/PERFORMANCE or XXXX CONTROL CIRCUIT OPEN DTCs?

Yes


No

2. RUN ACTUATOR CALIBRATION TEST

With the scan tool, select System Tests and then select Actuator Calibration Test. When the test is complete, select View DTCs.

Does the scan tool display any DTCs?

Yes


No

3. CHECK MODE, BLEND & RECIRCULATION DOOR OPERATION

Start the engine.
Set the blower to high speed.
Verify that air flows from the correct vents while setting the Mode control to the Panel position, the Bilvel position, the Floor/Defrost position, and the Defrost position. Then, repeat in the opposite direction.
Set the Mode control to the Panel position.
Set the Driver Blend control to the full cold position.
Set the Passenger Blend control the full cold position.
Verify that the airflow air temperature changes while setting the Driver Blend control to the full hot position. Then, repeat in the opposite direction.
Verify that the airflow air temperature changes while setting the Passenger Blend control to the full hot position. Then, repeat in the opposite direction.
Set the Mode control to any position between Floor and Panel.
Press the Recirc function on. Verify that the sound of the airflow gets louder as the recirculation door opens to bring in recirculated air.
Press the Recirc function off. Verify that the sound of the airflow gets softer as the recirculation door closes to bring in fresh air.

Does each door operate properly?

Yes


No