2007 Liberty KJ Factory Service Manual 8 - ELECTRICAL

*TEMP DISPLAY INOPERATIVE OR WRONG

For a complete wiring diagram Refer to Section 8W.



Possible Causes
 
AMBIENT TEMPERATURE SENSOR
 
EVIC INOPERATIVE
 




Diagnostic Test

1. AMBIENT TEMPERATURE SENSOR

NOTE: Diagnose and repair any PCM, EVIC, or Communication DTCs before proceeding with this test.


NOTE: The Ambient Temperature Sensor is hardwired to the PCM. Ambient temperature information is transmitted to the EVIC via the PCI Bus.


Turn the ignition off.
Disconnect the Ambient Temperature Sensor harness connector.
Measure the resistance of the Ambient Temperature Sensor using the following temperature/resistance values:
10°C (50°F) Sensor Resistance = 17.99 - 21.81 Kilohms
20°C (68°F) Sensor Resistance = 11.37 - 13.61 Kilohms
25°C (77°F) Sensor Resistance = 9.12 - 10.88 Kilohms
30°C (86°F) Sensor Resistance = 7.37 - 8.75 Kilohms
40°C (104°F) Sensor Resistance = 4.90 - 5.75 Kilohms
50°C (122°F) Sensor Resistance = 3.33 - 3.88 Kilohms

Is the Ambient Temperature Sensor resistance measurement between the min/max specifications?

Yes


No

2. EVIC INOPERATIVE

Perform the EVIC self test.
Turn the ignition off.
Press and hold the C/T and Reset buttons.
Turn the ignition on.

NOTE: The self test can also be performed using the scan tool.


Observe the EVIC display at the conclusion of the self test.

Does the EVIC display "PASSED SELF TEST"?

Yes


No