Connector — LAMP-DOME
3 way
| Cavity | Description | Circuit |
|---|---|---|
| 1 | GROUND | Z327 20BK/WT |
| 2 | FUSED B(+) | A908 18RD |
| 2 | COURTESY LAMP LOAD SHED | M20 20YL/LB |
| 3 | GROUND | Z327 20RD |
| 3 | FUSED B(+) | A908 20RD |
8W-12 JUNCTION BLOCK
3 way
| Cavity | Description | Circuit |
|---|---|---|
| 1 | GROUND | Z327 20BK/WT |
| 2 | FUSED B(+) | A908 18RD |
| 2 | COURTESY LAMP LOAD SHED | M20 20YL/LB |
| 3 | GROUND | Z327 20RD |
| 3 | FUSED B(+) | A908 20RD |