INSTALLATION
INSTALLATION
-
Select a wire from the terminal repair kit that best matches the color and gage of the wire being repaired.
-
Cut the repair wire to the proper length and remove one–half (1/2) inch of insulation.
-
Splice the repair wire to the wire harness (see wire splicing procedure) (Refer to 29 - Non-DTC Diagnostics/Circuit Testing Procedures - Standard Procedure)
.
-
Insert the repaired wire into the connector.
-
Install the connector locking wedge, if required, and reconnect the connector to its mating half/component.
-
Re-tape the wire harness starting at 1–1/2 inches behind the connector and 2 inches past the repair.
-