U110D-LOST COMMUNICATION WITH SECURITY SIREN
For a complete wiring diagram, refer to the Wiring Information.
-
When Monitored:
Continuously while the VTSS is armed.
-
Set Condition:
If the Intrusion Transceiver Module does not receive messages from the Siren.
Possible Causes |
|---|
| INTERMITTENT CONDITION |
| (A412) FUSED B+ CIRCUIT OPEN |
| (Z905) GROUND CIRCUIT OPEN |
| (D122) SIREN SIGNAL CONTROL CIRCUIT SHORT TO BATTERY |
| (D122) SIREN SIGNAL CONTROL CIRCUIT OPEN |
| (D122) SIREN SIGNAL CONTROL CIRCUIT SHORT TO GROUND |
| SIREN |
| INTRUSION TRANSCEIVER MODULE |
| 1. | With the scan tool, erase the current Intrusion Transceiver Module DTCs. |
| 2. | Turn the ignition off. |
| 3. | Arm the VTSS and wait one minute. |
| 4. | Disarm the VTSS and turn the ignition on. |
| 5. | With the scan tool, read ITM DTC(s). |
Does the scan tool display the same DTC?
Yes
- Go To 2
No
- The condition that caused this symptom is currently not present. Inspect the related wiring harness for a possible intermittent condition. Look for any chafed, pierced, pinched or partially broken wires.
-
Perform the
BODY VERIFICATION TEST. (Refer
to 28 - DTC-Based Diagnostics/MODULE, Totally Integrated Power (TIPM)
- Standard Procedure).
| 1. | Turn the ignition off. |
| 2. | Gain access to the VTSS Siren. |
| 3. | Disconnect the Siren connector. |
| 4. | Using a 12-volt test light connected to ground, check the (A412) Fused B(+) circuit in the Siren connector. |
Does the test light illuminate brightly?
Yes
- Go To 3
No
- Repair the (A412) Fused B+ circuit for an open. Inspect the related fuse. If the fuse is open, check the circuit for a short to ground.
-
Perform the
BODY VERIFICATION TEST. (Refer
to 28 - DTC-Based Diagnostics/MODULE, Totally Integrated Power (TIPM)
- Standard Procedure).
| 1. | Using a 12-volt test light connected to 12-volts, check the (Z905) Ground circuit at the Siren connector. |
Does the test light illuminate brightly?
Yes
- Go To 4
No
- Repair the (Z905) Ground circuit for an open.
-
Perform the
BODY VERIFICATION TEST. (Refer
to 28 - DTC-Based Diagnostics/MODULE, Totally Integrated Power (TIPM)
- Standard Procedure).
| 2. | Disconnect the Siren connector. |
| 3. | Connect the black lead to the chassis ground. Connect the red lead to the (D122) Siren Signal Control circuit in the Siren connector. |
| 4. | Close all doors and arm the VTSS. |
| 5. | Observe the voltage displayed on the DRBIII® Lab Scope. |
Is there a voltage square wave present 1 to 2 seconds?
Yes
- Connect a known good Siren and try to reset the DTC. If the DTC does not reset the original Siren needs to be replaced. If the DTC does reset replace the Intrusion Transceiver Module in accordance with the Service Information.
- Perform the BODY VERIFICATION TEST. (Refer to 28 - DTC-Based Diagnostics/MODULE, Totally Integrated Power (TIPM) - Standard Procedure).
No
-
Go To 5
5. (D122) SIREN SIGNAL CONTROL CIRCUIT SHORT TO BATTERY
| 1. | Disconnect the Siren harness connector. |
| 2. | Turn the ignition on. |
| 3. | Measure the voltage of the (D122) Siren Signal Control circuit. |
Is there any voltage present?
Yes
- Repair the (D122) Siren Signal Control circuit for a short to voltage.
- Perform the BODY VERIFICATION TEST. (Refer to 28 - DTC-Based Diagnostics/MODULE, Totally Integrated Power (TIPM) - Standard Procedure).
No
-
Go To 6
6. (D122) SIREN SIGNAL CONTROL CIRCUIT SHORT TO GROUND
| 1. | Turn the ignition off. |
| 2. | Disconnect the Intrusion Transceiver Module harness connector. |
| 3. | Measure the resistance between ground and the (D122) Siren Signal Control circuit. |
Is the resistance above 5.0 Ohms?
Yes
- Go To 7
No
- Repair the (D122) Siren Signal Control circuit for a short to ground.
-
Perform the
BODY VERIFICATION TEST. (Refer
to 28 - DTC-Based Diagnostics/MODULE, Totally Integrated Power (TIPM)
- Standard Procedure).
7. (D122) SIREN SIGNAL CONTROL CIRCUIT OPEN
| 1. | Measure the resistance of the (D122) Siren Signal Control circuit between the Intrusion Transceiver Module and the Siren connector. |
Is the resistance below 5.0 Ohms?
Yes
- Replace the Intrusion Transceiver Module in accordance with the Service Information.
- Perform the BODY VERIFICATION TEST. (Refer to 28 - DTC-Based Diagnostics/MODULE, Totally Integrated Power (TIPM) - Standard Procedure).
No
- Repair the (D122) Siren Signal Control circuit for an open.
-
Perform the
BODY VERIFICATION TEST. (Refer
to 28 - DTC-Based Diagnostics/MODULE, Totally Integrated Power (TIPM)
- Standard Procedure).