CONNECTOR TERMINAL INSTALLATION
-
Select a wire from
the terminal repair kit that best matches the color and gauge of the
wire being repaired.
-
Cut the repair wire
to the proper length and remove one–half (1/2) inch of insulation.
-
Splice the repair wire
to the wire harness (see Wire Splicing procedure) (Refer to 29 - Non-DTC Diagnostics/Circuit
Testing Procedures - Standard Procedure)
.
-
Insert the repaired
wire into the connector.
-
Install the connector
locking wedge, if required, and reconnect the connector to its mating
half/component.
-
Re-tape the wire harness
starting at 1–1/2 inches behind the connector and 2 inches past the
repair.
-
Connect battery and
test all affected systems.