A/C Compressor Relief Valve Replacement - Without Climate Control
A/C Compressor Relief Valve Replacement - Without Climate Control
D17A2 Engine Model
| 1. | Discharge the refrigerant. |
| 2. | Remove the cover (A), the relief valve (B), and the O-ring (C). Plug the opening to keep foreign matter from entering the system and the compressor oil from running out.
9.8 N·m (1.0 kgf·m, 7.2 lbf·ft)AC |
| 3. | Clean the mating surfaces. |
| 4. | Replace the O-ring with a new one at the relief valve, and apply a thin coat of refrigerant oil before installing it. |
| 5. | Remove the plug, and install and tighten the relief valve. |
| 6. | Evacuate the system. |
| 7. | Charge the system. |
| 8. | Check for system performance. |