INSPECTION
Inspection
| INSPECT INTEGRATION RELAY |
- NOTICE:
- Some relays are built into the integration relay (unit: A). The integration relay cannot be disassembled. If there is a malfunction in the circuit of the integration relay, replace the integration relay.
- The internal circuit of the integration relay is as shown in the illustration. Inspect the integration relay using the following procedures.


- Some relays are built into the integration relay (unit: A). The integration relay cannot be disassembled. If there is a malfunction in the circuit of the integration relay, replace the integration relay.
Measure the resistance of the C/OPN relay.

Using an ohmmeter, measure the resistance between terminal.
- Standard resistance:
Tester Connection
Specified Condition
2B-5 - 2B-8
10 kΩ or higher
Connect the battery's positive (+) lead to terminals 2B-5 and negative (-) lead to terminal 2B-7. Using an voltmeter, measure the resistance between terminal.
- Standard voltage:
Tester Connection
Specified Condition
2B-7 - 2B-8
10 - 14V
Measure the resistance of the EFI MAIN relay.

Remove the EFI fuse. Using an ohmmeter, measure the resistance between the terminals.
- Standard resistance:
Tester Connection
Specified Condition
EFI fuse terminal 2 - 2A-8
10 kΩ or higher
Connect the battery's positive (+) lead to terminal 2A-6 and negative (-) lead to terminal 2A-7. Using an ohmmeter, measure the resistance between terminal.
- Standard resistance:
Tester Connection
Specified Condition
EFI fuse terminal 2 - terminal 2A-8
Below 1 Ω
Measure the resistance of the EFI NO. 2 relay.

Remove the F/PMP fuse. Using an ohmmeter, measure the resistance between the terminals.
- Standard resistance:
Tester Connection
Specified Condition
F-PMP fuse terminal 2 - 2B-4
10 kΩ or higher
Connect the battery's positive (+) lead to terminal 2A-8 and negative (-) lead to terminal 2B-3. Using an ohmmeter, measure the resistance between the terminals.
- Standard resistance:
Tester Connection
Specified Condition
F-PMP fuse terminal 2 - 2B-4
Below 1 Ω
Measure the resistance of the EFI INJ relay.

Remove the INJ fuse. Using an ohmmeter, measure the resistance between the terminals.
- Standard resistance:
Tester Connection
Specified Condition
INJ fuse terminal 2 - 2A-4
10 kΩ or higher
Connect the battery's positive (+) lead to terminal 2A-2 and negative (-) lead to terminal 2A-3. Using an ohmmeter, measure the resistance between the terminals.
- Standard resistance:
Tester Connection
Specified condition
INJ fuse terminal 2 - terminal 2A-4
Below 1 Ω