INSPECTION
Inspection
| INSPECT FRONT POWER SEAT SWITCH LH |
Measure the resistance between the specified terminals when each switch is operated.

- Standard resistance (Slide switch):
Tester Connection
Switch Condition
Specified Condition
1 (B) - 9 (SLDF)
FRONT
Below 1 Ω
4 (E) - 6 (SLDR)
FRONT
Below 1 Ω
1 (B) - 6 (SLDR)
FRONT
10 kΩ or higher
4 (E) - 9 (SLDF)
FRONT
10 kΩ or higher
4 (E) - 6 (SLDR)
OFF
Below 1 Ω
4 (E) - 9 (SLDF)
OFF
Below 1 Ω
1 (B) - 6 (SLDR)
OFF
10 kΩ or higher
1 (B) - 9 (SLDF)
OFF
10 kΩ or higher
1 (B) - 6 (SLDR)
REAR
Below 1 Ω
4 (E) - 9 (SLDF)
REAR
Below 1 Ω
1 (B) - 9 (SLDF)
REAR
10 kΩ or higher
4 (E) - 6 (SLDR)
REAR
10 kΩ or higher
- Standard resistance (Front vertical switch):
Tester Connection
Switch Condition
Specified Condition
1 (B) - 10 (FUP)
UP
Below 1 Ω
4 (E) - 5 (FDWN)
UP
Below 1 Ω
1 (B) - 5 (FDWN)
UP
10 kΩ or higher
4 (E) - 10 (FUP)
UP
10 kΩ or higher
4 (E) - 5 (FDWN)
OFF
Below 1 Ω
4 (E) - 10 (FUP)
OFF
Below 1 Ω
1 (B) - 5 (FDWN)
OFF
10 kΩ or higher
1 (B) - 10 (FUP)
OFF
10 kΩ or higher
1 (B) - 5 (FDWN)
DOWN
Below 1 Ω
4 (E) - 10 (FUP)
DOWN
Below 1 Ω
1 (B) - 10 (FUP)
DOWN
10 kΩ or higher
4 (E) - 5 (FDWN)
DOWN
10 kΩ or higher
- Standard resistance (Lifter switch):
Tester Connection
Switch Condition
Specified Condition
1 (B) - 7 (LUP)
UP
Below 1 Ω
4 (E) - 8 (LDWN)
UP
Below 1 Ω
1 (B) - 8 (LDWN)
UP
10 kΩ or higher
4 (E) - 7 (LUP)
UP
10 kΩ or higher
4 (E) - 7 (LUP)
OFF
Below 1 Ω
4 (E) - 8 (LDWN)
OFF
Below 1 Ω
1 (B) - 7 (LUP)
OFF
10 kΩ or higher
1 (B) - 8 (LDWN)
OFF
10 kΩ or higher
1 (B) - 8 (LDWN)
DOWN
Below 1 Ω
4 (E) - 7 (LUP)
DOWN
Below 1 Ω
1 (B) - 7 (LUP)
DOWN
10 kΩ or higher
4 (E) - 8 (LDWN)
DOWN
10 kΩ or higher
- Standard resistance (Reclining switch):
Tester Connection
Switch Condition
Specified Condition
1 (B) - 3 (RCLF)
FRONT
Below 1 Ω
4 (E) - 2 (RCLR)
FRONT
Below 1 Ω
1 (B) - 2 (RCLR)
FRONT
10 kΩ or higher
4 (E) -3 (RCLF)
FRONT
10 kΩ or higher
4 (E) - 2 (RCLR)
OFF
Below 1 Ω
4 (E) - 3 (RCLF)
OFF
Below 1 Ω
1 (B) - 3 (RCLF)
OFF
10 kΩ or higher
1 (B) - 2 (RCLR)
OFF
10 kΩ or higher
1 (B) - 2 (RCLR)
REAR
Below 1 Ω
4 (E) - 3 (RCLF)
REAR
Below 1 Ω
1 (B) - 3 (RCLF)
REAR
10 kΩ or higher
4 (E) - 2 (RCLR)
REAR
10 kΩ or higher
| INSPECT FRONT POWER SEAT SWITCH RH |
Measure the resistance between the specified terminals when each switch is operated.

- Standard resistance (Slide switch):
Tester Connection
Switch Condition
Specified Condition
1 (B) - 9 (SLDF)
FRONT
Below 1 Ω
4 (E) - 6 (SLDR)
FRONT
Below 1 Ω
1 (B) - 6 (SLDR)
FRONT
10 kΩ or higher
4 (E) - 9 (SLDF)
FRONT
10 kΩ or higher
4 (E) - 6 (SLDR)
OFF
Below 1 Ω
4 (E) - 9 (SLDF)
OFF
Below 1 Ω
1 (B) - 6 (SLDR)
OFF
10 kΩ or higher
1 (B) - 9 (SLDF)
OFF
10 kΩ or higher
1 (B) - 6 (SLDR)
REAR
Below 1 Ω
4 (E) - 9 (SLDF)
REAR
Below 1 Ω
1 (B) - 9 (SLDF)
REAR
10 kΩ or higher
4 (E) - 6 (SLDR)
REAR
10 kΩ or higher
- Standard resistance (Front vertical switch):
Tester Connection
Switch Condition
Specified Condition
1 (B) - 10 (FUP)
UP
Below 1 Ω
4 (E) - 5 (FDWN)
UP
Below 1 Ω
1 (B) - 5 (FDWN)
UP
10 kΩ or higher
4 (E) - 10 (FUP)
UP
10 kΩ or higher
4 (E) - 5 (FDWN)
OFF
Below 1 Ω
4 (E) - 10 (FUP)
OFF
Below 1 Ω
1 (B) - 5 (FDWN)
OFF
10 kΩ or higher
1 (B) - 10 (FUP)
OFF
10 kΩ or higher
1 (B) - 5 (FDWN)
DOWN
Below 1 Ω
4 (E) - 10 (FUP)
DOWN
Below 1 Ω
1 (B) - 10 (FUP)
DOWN
10 kΩ or higher
4 (E) - 5 (FDWN)
DOWN
10 kΩ or higher
- Standard resistance (Lifter switch):
Tester Connection
Switch Condition
Specified Condition
1 (B) - 7 (LUP)
UP
Below 1 Ω
4 (E) - 8 (LDWN)
UP
Below 1 Ω
1 (B) - 8 (LDWN)
UP
10 kΩ or higher
4 (E) - 7 (LUP)
UP
10 kΩ or higher
4 (E) - 7 (LUP)
OFF
Below 1 Ω
4 (E) - 8 (LDWN)
OFF
Below 1 Ω
1 (B) - 7 (LUP)
OFF
10 kΩ or higher
1 (B) - 8 (LDWN)
OFF
10 kΩ or higher
1 (B) - 8 (LDWN)
DOWN
Below 1 Ω
4 (E) - 7 (LUP)
DOWN
Below 1 Ω
1 (B) - 7 (LUP)
DOWN
10 kΩ or higher
4 (E) - 8 (LDWN)
DOWN
10 kΩ or higher
- Standard resistance (Reclining switch):
Tester Connection
Switch Condition
Specified Condition
1 (B) - 3 (RCLF)
FRONT
Below 1 Ω
4 (E) - 2 (RCLR)
FRONT
Below 1 Ω
1 (B) - 2 (RCLR)
FRONT
10 kΩ or higher
4 (E) -3 (RCLF)
FRONT
10 kΩ or higher
4 (E) - 2 (RCLR)
OFF
Below 1 Ω
4 (E) - 3 (RCLF)
OFF
Below 1 Ω
1 (B) - 3 (RCLF)
OFF
10 kΩ or higher
1 (B) - 2 (RCLR)
OFF
10 kΩ or higher
1 (B) - 2 (RCLR)
REAR
Below 1 Ω
4 (E) - 3 (RCLF)
REAR
Below 1 Ω
1 (B) - 3 (RCLF)
REAR
10 kΩ or higher
4 (E) - 2 (RCLR)
REAR
10 kΩ or higher