INSPECTION
Inspection
| INSPECT ENGINE SWITCH |
Measure the resistance according to the value(s) in the table below.


- Standard resistance:
Tester Connection
Switch Condition
Specified Condition
7 (SS1) - 5 (GND)
Pushed
Below 1 Ω
2 (SS2) - 5 (GND)
Pushed
Below 1 Ω
7 (SS1) - 5 (GND)
Not pushed
10 kΩ or higher
2 (SS2) - 5 (GND)
Not pushed
10 kΩ or higher
Apply battery voltage between the terminals of the switch, and check the illumination condition of the switch.


- Standard resistance:
Measurement Condition
Specified Condition
Battery positive (+) →Terminal 11 (SWIL) Battery negative (-) →Terminal 4 (COM) or 5 (GND)
Illuminates
Battery positive (+) →Terminal 12 (INDS) Battery negative (-) →Terminal 4 (COM) or 5 (GND)
Illuminates
Battery positive (+) →Terminal 13 (INDW) Battery negative (-) →Terminal 4 (COM) or 5 (GND)
Illuminates