INSPECTION
Inspection
| INSPECT A/C COMPRESSOR |
Measure the resistance according to the value(s) in the table below.

- Standard resistance:
Tester Connection
Condition
Specified Condition
E8-1 (MG+) - A-1
Always
Below 1 Ω
E8-1 (MG;) - Body ground
Always
10 kΩ or higher
| INSPECT MAGNETIC CLUTCH |
Measure the resistance of the connector.

- Standard resistance:
Tester Connection
Condition
Specified Condition
A-1 - Body ground
Always
3.4 to 3.8 Ω
When connector terminal A1 is connected to the positive (+) battery terminal, check that the following occurs: 1) the magnetic clutch's operating sound can be heard, and 2) the magnetic clutch's hub and rotor lock.
| INSPECT A/C COMPRESSOR (LOCK SENSOR) |
Measure the resistance according to the value(s) in the table below.

- Standard resistance:
Tester Connection
Specified Condition
E8-2 (SSR+) - E8-5 (SSR-)
160 to 320 Ω
| INSPECT A/C COMPRESSOR (SOLENOID) |
Measure the resistance according to the value(s) in the table below.

- Standard resistance:
Tester Connection
Condition
Specified Condition
E8-3 (SOL+) - E8-6 (SOL-)
20°C (68°F)