Title: 3UR-FE ENGINE CONTROL: SFI SYSTEM: DESCRIPTION (2008 LX570)

DTC

P0116

Engine Coolant Temperature Circuit Range / Performance Problem

DESCRIPTION

Refer to DTC P0115 3UR-FE ENGINE CONTROL: SFI SYSTEM: DESCRIPTION (2008 LX570)+ .

DTC Code

DTC Detection Condition

Trouble Area

P0116

When either of the following conditions is met (2 trip detection logic):

  • When a cold engine is started and the engine is warmed up, the Engine Coolant Temperature (ECT) sensor value does not change.
  • After the warmed up engine is stopped and then the next cold engine start is performed, the ECT sensor value does not change.
  • Water inlet sub-assembly with thermostat
  • ECT sensor

MONITOR DESCRIPTION

Engine coolant temperature (ECT) sensor cold start monitor

When a cold engine start is performed and then the engine is warmed up, if the ECT sensor value does not change, it is determined that a malfunction has occurred. If this is detected in 2 consecutive driving cycles, the MIL is illuminated and a DTC is stored.

ECT sensor soak monitor

If the ECT sensor value does not change after the warmed up engine is stopped and then the next cold engine start is performed, it is determined that a malfunction has occurred. If this is detected in 2 consecutive driving cycles, the MIL is illuminated and a DTC is stored.

MONITOR STRATEGY

Related DTCs

P0116: Engine coolant temperature (ECT) sensor cold start monitor

P0116: ECT sensor soak monitor

Required Sensors/Components (Main)

ECT sensor

Required Sensors/Components (Related)

None

Frequency of Operation

Once per driving cycle

Duration

10 seconds or more

MIL Operation

2 driving cycles

Sequence of Operation

None

TYPICAL ENABLING CONDITIONS

ECT sensor cold start monitor:

Monitor runs whenever following DTCs not stored

P0102 - P0103: Mass Air Flow (MAF) meter

P0110 - P0113: Intake Air Temperature (IAT) sensor

Battery voltage

10.5 V or higher

Time after engine start

1 second or more

ECT at engine start

Below 60°C (140°F)

IAT sensor circuit

OK

Soak time

0 seconds or more

Accumulated MAF

1,968 g or more

Fuel cut

OFF

Difference between ECT at engine start and IAT

Below 40°C (72°F)

ECT sensor soak monitor:

Monitor runs whenever following DTCs not stored

P0102 - P0103: MAF meter

Battery voltage

10.5 V or higher

Engine

Running

Soak time

5 hours or more

Either (a) or (b) condition met

-

(a) ECT

60°C (140°F) or higher

(b) Accumulated MAF

4,165 g or more

TYPICAL MALFUNCTION THRESHOLDS

ECT sensor cold start monitor:

ECT sensor value change

Below 5°C (9°F)

ECT sensor soak monitor:

Difference between current ECT sensor value and previous ECT sensor value when engine stopped

Below 3°C (5.4°F) [varies with ECT of last trip engine stop]

COMPONENT OPERATING RANGE

ECT

ECT sensor value changes in accordance with actual ECT

INSPECTION PROCEDURE

HINT:

  • If any of DTCs P0115, P0117, P0118 or P0125 is output simultaneously with DTC P0116, the ECT sensor may have an open or a short circuit. Troubleshoot those DTCs first.
  • Read freeze frame data using the Techstream. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.

PROCEDURE

1.

CHECK ANY OTHER DTCS OUTPUT (IN ADDITION TO DTC P0116)

(a) Connect the Techstream to the DLC3.

(b) Turn the engine switch on (IG).

(c) Turn the Techstream on.

(d) Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.

(e) Read the DTC.

Result

Result

Proceed to

P0116 is output

A

P0116 and other DTCs are output

B

A

2.

INSPECT WATER INLET SUB-ASSEMBLY WITH THERMOSTAT

(a) Remove the water inlet sub-assembly with thermostat 3UR-FE COOLING: THERMOSTAT: REMOVAL (2008 LX570) .

(b) Measure the valve opening temperature of the water inlet sub-assembly with thermostat.

Standard opening temperature:

80 to 84°C (176 to 183°F)

HINT:

In addition to the above check, confirm that the valve is completely closed when the temperature is below the standard.

(c) Reinstall the water inlet sub-assembly with thermostat 3UR-FE COOLING: THERMOSTAT: INSTALLATION (2008 LX570) .

OK