Title: 3UR-FE ENGINE CONTROL: SFI SYSTEM: DESCRIPTION (2008 LX570) |
|
DTC
|
P0116
|
Engine Coolant Temperature Circuit Range / Performance Problem
|
DESCRIPTION
Refer to DTC P0115
.
|
DTC Code
|
DTC Detection Condition
|
Trouble Area
|
|
P0116
|
When either of the following conditions is met (2 trip detection logic):
-
When a cold engine is started and the engine is warmed up, the Engine Coolant Temperature (ECT) sensor value does not change.
-
After the warmed up engine is stopped and then the next cold engine start is performed, the ECT sensor value does not change.
|
-
Water inlet sub-assembly with thermostat
-
ECT sensor
|
MONITOR DESCRIPTION
Engine coolant temperature (ECT) sensor cold start monitor
When a cold engine start is performed and then the engine is warmed up, if the ECT sensor value does not change, it is determined that a malfunction has occurred. If this is detected in 2 consecutive driving cycles, the MIL is illuminated and a DTC is stored.
ECT sensor soak monitor
If the ECT sensor value does not change after the warmed up engine is stopped and then the next cold engine start is performed, it is determined that a malfunction has occurred. If this is detected in 2 consecutive driving cycles, the MIL is illuminated and a DTC is stored.
MONITOR STRATEGY
|
Related DTCs
|
P0116: Engine coolant temperature (ECT) sensor cold start monitor
P0116: ECT sensor soak monitor
|
|
Required Sensors/Components (Main)
|
ECT sensor
|
|
Required Sensors/Components (Related)
|
None
|
|
Frequency of Operation
|
Once per driving cycle
|
|
Duration
|
10 seconds or more
|
|
MIL Operation
|
2 driving cycles
|
|
Sequence of Operation
|
None
|
TYPICAL ENABLING CONDITIONS
ECT sensor cold start monitor:
|
Monitor runs whenever following DTCs not stored
|
P0102 - P0103: Mass Air Flow (MAF) meter
P0110 - P0113: Intake Air Temperature (IAT) sensor
|
|
Battery voltage
|
10.5 V or higher
|
|
Time after engine start
|
1 second or more
|
|
ECT at engine start
|
Below 60°C (140°F)
|
|
IAT sensor circuit
|
OK
|
|
Soak time
|
0 seconds or more
|
|
Accumulated MAF
|
1,968 g or more
|
|
Fuel cut
|
OFF
|
|
Difference between ECT at engine start and IAT
|
Below 40°C (72°F)
|
ECT sensor soak monitor:
|
Monitor runs whenever following DTCs not stored
|
P0102 - P0103: MAF meter
|
|
Battery voltage
|
10.5 V or higher
|
|
Engine
|
Running
|
|
Soak time
|
5 hours or more
|
|
Either (a) or (b) condition met
|
-
|
|
(a) ECT
|
60°C (140°F) or higher
|
|
(b) Accumulated MAF
|
4,165 g or more
|
TYPICAL MALFUNCTION THRESHOLDS
ECT sensor cold start monitor:
|
ECT sensor value change
|
Below 5°C (9°F)
|
ECT sensor soak monitor:
|
Difference between current ECT sensor value and previous ECT sensor value when engine stopped
|
Below 3°C (5.4°F) [varies with ECT of last trip engine stop]
|
COMPONENT OPERATING RANGE
|
ECT
|
ECT sensor value changes in accordance with actual ECT
|
INSPECTION PROCEDURE
HINT:
-
If any of DTCs P0115, P0117, P0118 or P0125 is output simultaneously with DTC P0116, the ECT sensor may have an open or a short circuit. Troubleshoot those DTCs first.
-
Read freeze frame data using the Techstream. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.
PROCEDURE
|
1.
|
CHECK ANY OTHER DTCS OUTPUT (IN ADDITION TO DTC P0116)
|
(a) Connect the Techstream to the DLC3.
(b) Turn the engine switch on (IG).
(c) Turn the Techstream on.
(d) Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
(e) Read the DTC.
Result
|
Result
|
Proceed to
|
|
P0116 is output
|
A
|
|
P0116 and other DTCs are output
|
B
|
| A |
|
|
|
2.
|
INSPECT WATER INLET SUB-ASSEMBLY WITH THERMOSTAT
|
(a) Remove the water inlet sub-assembly with thermostat
.
(b) Measure the valve opening temperature of the water inlet sub-assembly with thermostat.
Standard opening temperature:
80 to 84°C (176 to 183°F)
HINT:
In addition to the above check, confirm that the valve is completely closed when the temperature is below the standard.
(c) Reinstall the water inlet sub-assembly with thermostat
.
| OK |
|
|
|