RX400h · Service Manual HYBRID SYSTEM

ADJUSTMENT

Removal / installation


1. ADJUST PARK/NEUTRAL POSITION SWITCH

  1. C108753
    Loosen the 2 bolts of park/neutral position switch and set the shift lever to the N position.

  1. C090076E01
    Align the protruding part and neutral basic line.

    NOTICE:
    There is play on the nut stopper side (protruding part). Align the center point of the range of the play with the neutral basic line.

  1. C108753E01
    Tighten the 2 bolts in the order shown in the illustration.

    Torque:
    13 N*m{ 133 kgf*cm , 10 ft.*lbf }


2. INSPECT PARK/NEUTRAL POSITION SWITCH

  1. G029274E02
    Measure the resistance according to the value(s) in the table below.

    Standard resistance:

    A-1 (D)
    A-2 (N)
    A-3 (P)
    A-4 (R)
    A-5 (MJ)
    A-6 (FD)
    A-7 (B)
    A-9 (RV)
    P position
    10 kΩ or higher
    4.2 to 5.1 kΩ
    Below 1 Ω
    10 kΩ or higher
    Below 1 Ω
    10 kΩ or higher
    10 kΩ or higher
    10 kΩ or higher
    R position
    10 kΩ or higher
    4.2 to 5.1 kΩ
    10 kΩ or higher
    Below 1 Ω
    Below 1 Ω
    10 kΩ or higher
    10 kΩ or higher
    Below 1 Ω
    N position
    10 kΩ or higher
    Below 1 Ω
    10 kΩ or higher
    10 kΩ or higher
    Below 1 Ω
    10 kΩ or higher
    10 kΩ or higher
    10 kΩ or higher
    D position
    Below 1 Ω
    4.2 to 5.1 kΩ
    10 kΩ or higher
    10 kΩ or higher
    Below 1 Ω
    Below 1 Ω

    10 kΩ or higher
    B position
    10 kΩ or higher
    4.2 to 5.1 kΩ
    10 kΩ or higher
    10 kΩ or higher
    Below 1 Ω
    Below 1 Ω
    Below 1 Ω
    10 kΩ or higher

← INSPECTIONINSTALLATION →