B1413/13
Diagnostic trouble codes
DESCRIPTION
The A/C evaporator temperature sensor (A/C thermistor) is installed on the evaporator in the air conditioner unit to detect the cooled air temperature that has passed through the evaporator and control the air conditioning. It sends appropriate signals to the A/C amplifier assembly. The resistance of the A/C evaporator temperature sensor (A/C thermistor) changes in accordance with the cooled air temperature that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.The A/C amplifier assembly applies voltage (5 V) to the A/C evaporator temperature sensor (A/C thermistor) and reads voltage changes as the resistance of the A/C evaporator temperature sensor (A/C thermistor) changes. This sensor is used for frost prevention.
| DTC No. |
DTC Detecting Condition |
Trouble Area |
| B1413/13 |
Open or short in evaporator temperature sensor circuit |
|
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. READ VALUE OF INTELLIGENT TESTER |
Connect the intelligent tester to the DLC3.
Turn the ignition switch ON and push the intelligent tester main switch on.
Select the item below in the DATA LIST, and read the display on the intelligent tester.
| Item |
Measurement Item/Display (Range) |
Normal Condition |
Diagnostic Note |
| EVAP TEMP |
Evaporator temperature sensor / min.: -29.7°C (-21.46°F) max.: 59.55°C (139.19°F) |
Actual evaporator temperature is displayed |
Open in the circuit: -29.7°C (-21.46°F) Short in the circuit: 59.55°C (139.19°F) |
- OK:
- The display is as specified in the normal condition.
- Result:
Result
Proceed to
NG
A
OK (Checking from the PROBLEM SYMPTOMS TABLE)
B
OK (Checking from the DTC)
C
|
|
||||
|
|
||||
| A | |
| 2. INSPECT AIR CONDITIONING AMPLIFIER ASSEMBLY |
Remove the A/C amplifier assembly with the connectors still connected.

Measure the voltage according to the table value(s) in the table below.
- Voltage:
Tester connection
(Symbols)
Condition
Specified condition
A10-12 (TE) - A10-11 (SG)
Ignition switch ON
at 0°C (32°F)
2.2 to 2.6 V
A10-12 (TE) - A10-11 (SG)
Ignition switch ON
at 15°C (59°F)
1.3 to 1.7 V
- HINT:
- As the temperature increases, the voltage decreases.
- Result:
Result
Proceed to
NG
A
OK (Checking from the PROBLEM SYMPTOMS TABLE)
B
OK (Checking from DTC)
C
|
|
||||
|
|
||||
| A | |
| 3. INSPECT A/C EVAPORATOR TEMPERATURE SENSOR |
Remove the A/C evaporator temperature sensor (A/C thermistor).

Disconnect the connector from the A/C evaporator temperature sensor (A/C thermistor).
Measure the resistance according to the value(s) in the table below.


- Resistance:
Tester connection
Condition
Specified condition
A14-1 - A14-2
-10°C (14°F)
7.30 to 9.10 kΩ
A14-1 - A14-2
-5°C (23°F)
5.65 to 6.95 kΩ
A14-1 - A14-2
0°C (32°F)
4.40 to 5.35 kΩ
A14-1 - A14-2
5°C (41°F)
3.40 to 4.15 kΩ
A14-1 - A14-2
10°C (50°F)
2.70 to 3.25 kΩ
A14-1 - A14-2
15°C (59°F)
2.14 to 2.58 kΩ
A14-1 - A14-2
20°C (68°F)
1.71 to 2.05 kΩ
A14-1 - A14-2
25°C (77°F)
1.38 to 1.64 kΩ
A14-1 - A14-2
30°C (86°F)
1.11 to 1.32 kΩ
- NOTICE:
- Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
- When measuring, the sensor temperature must be the same as the ambient temperature .
- Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
- HINT:
- As the temperature increases, the resistance decreases (see the graph).
|
|
||||
| OK | |
| 4. CHECK HARNESS AND CONNECTOR (A/C EVAPORATOR TEMPERATURE SENSOR - A/C AMPLIFIER ASSEMBLY) |
Disconnect the connector from the A/C amplifier assembly.

Measure the resistance according to the value(s) in the table below.
- Resistance:
Tester connection
(Symbols)
Condition
Specified condition
A10-12 (TE) - A14-2
Always
Below 1 Ω
A10-11 (SG) - A14-1
Always
Below 1 Ω
A10-12 (TE) - Body ground
Always
10 kΩ or higher
A10-11 (SG) - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | ||
| ||