P0A94-556
Diagnostic trouble codes
DESCRIPTION
Refer to the description of the boost converter. (Click here)| DTC No. |
INF Code |
DTC Detection Condition |
Trouble Area |
| P0A94 |
556 |
Boost converter inverter fail signal detection (overcurrent by HV transaxle assembly malfunction) |
|
MONITOR DESCRIPTION
If over-amperage flows through the boost converter due to an internal short, the boost converter transmits a boost converter fail signal to the MG ECU. Upon receiving this signal, the HV control ECU illuminates the MIL and sets a DTC.INSPECTION PROCEDURE
- CAUTION:
- Before inspecting the high-voltage system, take safety precautions to prevent electrical shocks, such as wearing insulated gloves and removing the service plug grip. After removing the service plug grip, put it in your pocket to prevent other technicians from reconnecting it while you are working on the high-voltage system.
- After disconnecting the service plug grip, wait for at least 5 minutes before touching any of the high-voltage connectors or terminals.
- Before inspecting the high-voltage system, take safety precautions to prevent electrical shocks, such as wearing insulated gloves and removing the service plug grip. After removing the service plug grip, put it in your pocket to prevent other technicians from reconnecting it while you are working on the high-voltage system.
- HINT:
- At least 5 minutes is required to discharge the high-voltage capacitor inside the w/ converter inverter assembly.
| 1. READ OUTPUT DTC (HV) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to the ON position.
Select the following menu items: Powertrain / Hybrid Control / DTC.
Read output DTC. (Click here)
- Result:
- The DTCs shown in the table below are output:
DTC No.
Relevant Diagnosis
P0A1D
HV control ECU malfunction
P0A2B, P0A2C, P0A2D
Motor temperature sensor circuit
P0A37, P0A38, P0A39
Generator temperature sensor circuit
P0A3F, P0A40, P0A41
Motor resolver circuit
P0A4B, P0A4C, P0A4D
Generator resolver circuit
P0A60, P0A63
Motor current sensor circuit
P0A72, P0A75
Generator current sensor circuit
P0A78
Motor inverter function malfunction
P0A7A
Generator inverter function malfunction
P0A90
Motor function malfunction
P0A92
Generator function malfunction
P0A94 (Except for 556)
Boost converter function malfunction
P0AA1, P0AA2, P0AA4, P0AA5
System main relay circuit
P0AA6, P3004
High-voltage system
P0A79
Rear motor inverter function malfunction
P0A45, P0A46, P0A47
Rear motor resolver malfunction
P0A69, P0A6C, P0A55
Rear motor current sensor malfunction
- HINT:
- Turning the ignition switch to the ON position with the service plug grip and inverter cover removed causes interlock switch system DTC P0A0D-350 to be output.
- P0A78-284 may be output due to a malfunction which causes the DTCs in the table above to be output. In this case, first troubleshoot the output DTCs in the table above. Then, perform a reproduction test to check that no DTCs are output.
- Turning the ignition switch to the ON position with the service plug grip and inverter cover removed causes interlock switch system DTC P0A0D-350 to be output.
|
|
||||
| NO | |
| 2. CHECK CONNECTION CONDITION OF MG ECU CONNECTOR (LOOSENESS AND POOR CONTACT) |
- CAUTION:
- Be sure to wear insulated gloves.
Turn the ignition switch off and remove the service plug grip. (Click here)
- NOTICE:
- Do not put the vehicle into the READY-on state with the service plug grip removed as this may cause a malfunction.
Remove the inverter cover. (Click here)
- NOTICE:
- Wrap the interlock round terminal for the inverter cover with vinyl tape to prevent it from shorting to ground.
- Prevent water in the reservoir tank from entering the inverter.
- Removing the inverter cover causes the MG ECU board to be exposed. Therefore, temporarily install the inverter cover for each area to be inspected.
- Wrap the interlock round terminal for the inverter cover with vinyl tape to prevent it from shorting to ground.
Check the connections of the MG ECU connectors.

- OK:
- Connectors are connected securely and there is no poor connection.
|
|
||||
| OK | |
| 3. CONFIRM INFORMATION (EXCLUSIVE INFO 4) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to the ON position.
Select the following menu items: Powertrain / Hybrid Control / DTC.
Read output DTC.
- HINT:
- Turning the ignition switch to the ON position with the service plug grip and inverter cover removed causes interlock switch system DTC P0A0D-350 to be output.
Display freeze frame data corresponding to DTC P0A94 and select the information.
Select INF code 556 and read "Exclusive Info 4".
- Result:
Displayed item in exclusive information 4
Proceed to
-63 to 64
A
65 to 128
B
|
|
||||
| A | |
| 4. CHECK HARNESS AND CONNECTOR (MG ECU - MOTOR RESOLVER) |
Disconnect the I24 connector from the MG ECU.

Measure the voltage according to the value(s) in the table below when the ignition switch is in the ON position.
- Standard Voltage:
Tester Connection
Specified Condition
MRF (I24-13) - Body ground
Below 1 V
MRFG (I24-23) - Body ground
Below 1 V
MSN (I24-21) - Body ground
Below 1 V
MSNG (I24-20) - Body ground
Below 1 V
MCS (I24-19) - Body ground
Below 1V
MCSG (I24-18) - Body ground
Below 1 V
Turn the ignition switch off.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Specified Condition
MRF (I24-13) - MRFG (I24-23)
7.65 to 10.2 Ω
MSN (I24-21) - MSNG (I24-20)
12.6 to 16.8 Ω
MCS (I24-19) - MCSG (I24-18)
12.6 to 16.8 Ω
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Specified Condition
MRF (I24-13) or MRFG (I24-23) - Body ground
10 kΩ or higher
MSN (I24-21) or MSNG (I24-20) - Body ground
10 kΩ or higher
MCS (I24-19) or MCSG (I24-18) - Body ground
10 kΩ or higher
|
|
||||
| OK | |
| 5. CHECK HARNESS AND CONNECTOR (MG ECU - GENERATOR RESOLVER) |
Disconnect the I24 connector from the MG ECU.

Measure the voltage according to the value(s) in the table below when the ignition switch is in the ON position.
- Standard Voltage:
Tester Connection
Specified Condition
GRF (I24-12) - Body ground
Below 1 V
GRFG (I24-22) - Body ground
Below 1 V
GSN (I24-11) - Body ground
Below 1 V
GSNG (I24-10) - Body ground
Below 1 V
GCS (I24-9) - Body ground
Below 1 V
GCSG (I24-8) - Body ground
Below 1 V
Turn the ignition switch off.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Specified Condition
GRF (I24-12) - GRFG (I24-22)
7.65 to 10.2 Ω
GSN (I24-11) - GSNG (I24-10)
12.6 to 16.8 Ω
GCS (I24-9) - GCSG (I24-8)
12.6 to 16.8 Ω
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Specified Condition
GRF (I24-12) or GRFG (I24-22) - Body ground
10 kΩ or higher
GSN (I24-11) or GSNG (I24-10) - Body ground
10 kΩ or higher
GCS (I24-9) or GCSG (I24-8) - Body ground
10 kΩ or higher
|
|
||||
| OK | ||
| ||
| 6. CHECK HARNESS AND CONNECTOR (MG ECU - REAR MOTOR RESOLVER) |
Disconnect the I25 connector from the MG ECU.

Measure the voltage according to the value(s) in the table below when the ignition switch is in the ON position.
- Standard Voltage:
Tester Connection
Specified Condition
RRF (I25-21) - Body ground
Below 1 V
RRFG (I25-22) - Body ground
Below 1 V
RSN (I25-29) - Body ground
Below 1 V
RSNG (I25-30) - Body ground
Below 1 V
RCS (I25-11) - Body ground
Below 1 V
RCSG (I25-23) - Body ground
Below 1 V
Turn the ignition switch off.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Specified Condition
RRF (I25-21) - RRFG (I25-22)
7.65 to 10.2 Ω
RSN (I25-29) - RSNG (I25-30)
12.6 to 16.8 Ω
RCS (I25-11) - RCSG (I25-23)
12.6 to 16.8 Ω
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Specified Condition
RRF (I25-21) or RRFG (I25-22) - Body ground
10 kΩ or higher
RSN (I25-29) or RSNG (I25-30) - Body ground
10 kΩ or higher
RCS (I25-11) or RCSG (I25-23) - Body ground
10 kΩ or higher
|
|
||||
| OK | ||
| ||
| 7. CHECK CONNECTION CONDITION OF MOTOR RESOLVER CONNECTOR (LOOSENESS AND POOR CONTACT) |
Check the connections of the motor resolver connector.

- OK:
- Connectors are connected securely and there is no poor connection.
|
|
||||
| OK | |
| 8. INSPECT MOTOR RESOLVER |
Disconnect the M7 motor resolver connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Specified Condition
MRF (M7-1) - MRFG (M7-4)
7.65 to 10.2 Ω
MSN (M7-2) - MSNG (M7-5)
12.6 to 16.8 Ω
MCS (M7-3) - MCSG (M7-6)
12.6 to 16.8 Ω
Using a megohmmeter, measure the insulation resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Specified Condition
MRF (M7-1) - MSN (M7-2)
10 MΩ or higher
MRF (M7-1) - MCS (M7-3)
10 MΩ or higher
MSN (M7-2) - MCS (M7-3)
10 MΩ or higher
MRFG (M7-4) - MSNG (M7-5)
10 MΩ or higher
MRFG (M7-4) - MCSG(M7-6)
10 MΩ or higher
MSNG (M7-5) - MCSG (M7-6)
10 MΩ or higher
Each terminal listed above - Transaxle housing
10 MΩ or higher
|
|
||||
| OK | ||
| ||
| 9. CHECK CONNECTION CONDITION OF GENERATOR RESOLVER CONNECTOR (LOOSENESS AND POOR CONTACT) |
Remove the w/ converter inverter assembly.
Check the connections of the generator resolver connector.

- OK:
- Connectors are connected securely and there is no poor connection.
|
|
||||
| OK | |
| 10. INSPECT GENERATOR RESOLVER |
Disconnect the M6 generator resolver connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Specified Condition
GRF (M6-1) - GRFG (M6-6)
7.65 to 10.2 Ω
GSN (M6-2) - GSNG (M6-7)
12.6 to 16.8 Ω
GCS (M6-3) - GCSG (M6-8)
12.6 to 16.8 Ω
Using a megohmmeter, measure the insulation resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Specified Condition
GRF (M6-1) - GSN (M6-2)
10 MΩ or higher
GRF (M6-1) - GCS (M6-3)
10 MΩ or higher
GSN (M6-2) - GCS (M6-3)
10 MΩ or higher
GRFG (M6-6) - GSNG (M6-7)
10 MΩ or higher
GRFG (M6-6) - GCSG (M6-8)
10 MΩ or higher
GSNG (M6-7) - GCSG (M6-8)
10 MΩ or higher
Each terminal listed above - Transaxle housing
10 MΩ or higher
|
|
||||
| OK | ||
| ||
| 11. CHECK CONNECTION CONDITION OF REAR MOTOR RESOLVER CONNECTOR (LOOSENESS AND POOR CONTACT) |
Check the connections of the rear motor resolver connector.

- OK:
- Connectors are connected securely and there is no poor connection.
|
|
||||
| OK | |
| 12. INSPECT REAR MOTOR RESOLVER |
Remove the w/ converter inverter assembly.
Disconnect the M11 rear motor resolver connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Specified Condition
RRF (M11-1) - RRFG (M11-4)
7.65 to 10.2 Ω
RSN (M11-2) - RSNG (M11-5)
12.6 to 16.8 Ω
RCS (M11-3) - RCSG (M11-6)
12.6 to 16.8 Ω
Using a megohmmeter, measure the insulation resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Specified Condition
RRF (M11-1) - RSN (M11-2)
10 MΩ or higher
RRF (M11-1) - RCS (M11-3)
10 MΩ or higher
RSN (M11-2) - RCS (M11-3)
10 MΩ or higher
RRFG (M11-4) - RSNG (M11-5)
10 MΩ or higher
RRFG (M11-4) - RCSG (M11-6)
10 MΩ or higher
RSNG (M11-5) - RCSG (M11-6)
10 MΩ or higher
Each terminal listed above - Transaxle housing
10 MΩ or higher
|
|
||||
| OK | ||
| ||