INSPECTION
Inspection
| INSPECT FRONT SEAT CUSHION HEATER LH |
Measure the resistance according to the value(s) in the table below.

- Resistance:
Tester Connection
Condition
Specified Condition
A-1 - B-1
Seat heater temp. below 25 to 35°C (77 to 95°F)
8,000 to 8,400 Ω
A-1 - B-1
Seat heater temp. 46 to 54°C (115 to 129°F)
3,900 to 4,300 Ω
A-2 - A-3
Seat heater temp. below 25 to 35°C (77 to 95°F)
Below 1 Ω
A-2 - A-3
Seat heater temp. 46 to 54°C (115 to 129°F)
10 kΩ or higher (thermostat OFF)
A-4 - B-2
Always
Below 1 Ω
| INSPECT FRONT SEAT CUSHION HEATER RH |
Measure the resistance according to the value(s) in the table below.

- Resistance:
Tester Connection
Condition
Specified Condition
A-1 - B-1
Seat heater temp. below 25 to 35°C (77 to 95°F)
8,000 to 8,400 Ω
A-1 - B-1
Seat heater temp. 46 to 54°C (115 to 129°F)
3,900 to 4,300 Ω
A-2 - A-3
Seat heater temp. below 25 to 35°C (77 to 95°F)
Below 1 Ω
A-2 - A-3
Seat heater temp. 46 to 54°C (115 to 129°F)
10 kΩ or higher (thermostat OFF)
A-4 - B-2
Always
Below 1 Ω