RX400h · Service Manual BODY ELECTRICAL

INSPECTION

Inspection


INSPECT UNLOCK WARNING SWITCH ASSEMBLY

  1. B067252E01
    Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Switch Position
    Specified Condition
    1 - 2
    Free
    10 kΩ or higher
    1 - 2
    Pushed
    Below 1 Ω

← INSPECTIONINSPECTION →