INSPECTION
Inspection
| INSPECT FUEL SENDER GAUGE ASSEMBLY |
Check the operation of the float moving smoothly between F and E.

Disconnect the fuel sender gauge connector.
Remove the fuel sender gauge assembly.
Measure the resistance between the terminals 2 (FE) and 3 (FS) of connector according to the value(s) in the table below.
- Standard Resistance:
Float Level
Resistance (Ω)
F
13.5 to 16.5
E
405.5 to 414.5
- HINT:
- If the value is not as specified, replace the fuel sender gauge assembly.