Power Back Door Opener / Closer Switch Circuit
Circuit diagnosis
DESCRIPTION
The power back door opener/closer switch only turns on while the switch is being pressed, and turns off when the switch is released.The body ECU is connected to the power back door opener/closer switch via terminal PBDS and power back door operation request signals are input to the ECU.
The body ECU applies voltage to the power back door opener/closer switch via terminal PBDS. When the switch is on (there is continuity between the switch terminals), a power back door operation request signal is input to the body ECU to operate the back door.
- NOTICE:
- The power back door ECU records the back door positions in the memory. In the case where any of the batteries, fuses, power back door ECU and power back door drive unit are removed and then reinstalled, the power back door ECU loses the memory of the door positions. In such a case, resetting the power back door system is necessary. Refer to the resetting operation specified in page Click here.
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. READ VALUE OF DATA LIST (POWER BACK DOOR OPENER/CLOSER SWITCH) |
Check the DATA LIST to ensure proper functioning of the power back door opener/closer switch.
Body ECU Item
Measurement Item /
Display (Range)
Normal Condition
Diagnostic Note
B Door Open SW
Power back door opener/closer switch signal
/ON or OFF
ON: Power back door opener/ closer switch is pushed
OFF: Power back door opener/ closer switch is not pushed
-
- OK:
- The display is as specified in the normal condition.
|
|
||||
| OK | ||
| ||
| 2. INSPECT POWER BACK DOOR OPENER/CLOSER SWITCH ASSEMBLY |
Remove the power back door opener/closer switch assembly.

Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Switch Position
Specified Condition
3 - 4
Pushed (ON)
Below 1 Ω
3 - 4
Free (OFF)
10 kΩ or higher
|
|
||||
| OK | |
| 3. CHECK WIRE HARNESS (POWER BACK DOOR OPENER/CLOSER SWITCH - POWER BACK DOOR ECU) |
Disconnect the power back door opener/closer switch assembly connector.

Disconnect the instrument panel J/B connector.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
P7-3 - B7-2 (PBDS)
Always
Below 1 Ω
P7-4 - Body ground
Always
Below 1 Ω
|
|
||||
| OK | ||
| ||