INSPECTION
Inspection
| INSPECT HEATER WATER PUMP ASSEMBLY |
Remove the heater water pump assembly.
Disconnect the connector from the heater water pump assembly.

Connect the positive (+) lead terminal 2 of the heater water pump assembly connector and the negative (-) lead to terminal 1.
- OK:
- Heater water pump operates smoothly.
- NOTICE:
- Complete operation within 10 seconds if there is no water in the heater water pump assembly.