P0560-117
Diagnostic trouble codes
DESCRIPTION
- Battery power is constantly supplied to the BATT terminal of the HV control ECU for DTCs and freeze frame data memory even though the ignition switch is turned off.
| DTC No. |
INF Code |
DTC Detection Condition |
Trouble Area |
| P0560 |
117 |
HV control ECU back-up power source circuit malfunction |
|
MONITOR DESCRIPTION
If 3 or more seconds have elapsed with a voltage of less than 2.5 V at the BATT terminal in the HV control ECU, the HV control ECU will determine that a malfunction has occurred in the back-up power supply system, and set a DTC. The MIL will illuminate the next time the engine is started.WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. CHECK CONNECTION CONDITION OF HYBRID VEHICLE CONTROL ECU CONNECTOR (LOOSENESS AND POOR CONTACT) |
Check the connections of all HV control ECU connectors.

- OK:
- Connectors are connected securely and there is no poor connection.
|
|
||||
| OK | |
| 2. CHECK HARNESS AND CONNECTOR (HV CONTROL ECU - IGCT NO.5 FUSE) |
Turn the ignition switch OFF.
Remove the IGCT No.5 fuse from the engine room R/B No.4.
Disconnect the H29 connector from the HV control ECU.
Measure the resistance according to the value(s) in the table below.

- Standard Resistance (Check for open):
Tester Connection
Specified Condition
BATT (H29-1) - Engine room R/B No.4 IGCT No.5 fuse terminal 2
Below 1 Ω
- Standard Resistance (Check for short):
Tester Connection
Specified Condition
BATT (H29-1) or Engine room R/B No.4 IGCT No.5 fuse terminal 2 - Body ground
10 kΩ or more
- NOTICE:
- When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.
|
|
||||
| OK | |
| 3. CHECK HARNESS AND CONNECTOR (IGCT NO.5 FUSE - BATTEY POSITIVE TERMINAL) |
Disconnect the positive and negative cables from the auxiliary battery.
Measure the resistance according to the value(s) in the table below.

- Standard Resistance (Check for open):
Tester Connection
Specified Condition
Engine room R/B No.4 IGCT No.5 fuse terminal 1 - Battery positive terminal
Below 1 Ω
- Standard Resistance (Check for short):
Tester Connection
Specified Condition
Engine room R/B No.4 IGCT No.5 fuse terminal 1 - Body ground
10 kΩ or more
- NOTICE:
- When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.
|
|
||||
| OK | |
| 4. RECONFIRM OUTPUT DTC (HV) |
- HINT:
- If DTC P0560-117 is output again after performing the inspection, replace the HV control ECU. If the DTC is not output, there may be a malfunction in the wire harness or connector. Perform a check for intermittent problems.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to the ON position.
Select the following menu items: Powertrain / Hybrid Control / DTC.
Read output DTC. (Click here)
- Result:
- DTC P0560-117 is output again.
|
|
||||
| YES | ||
| ||