- Disconnect the negative battery cable. Remove the glove box, if necessary.
- Move the mode selection lever to the DEFROST position.
Move the mode selection damper lever FULLY INWARD and connect the cable
to the lever. Adjust as required.
- Move the temperature control lever to its HOTTEST position. Move the blend
air damper lever FULLY DOWNWARD and connect the cable to the lever. Adjust
as required.
- Move the air selection control lever to the RECIRC position.
Move the air selection damper FULLY INWARD and connect the cable to the
lever. Adjust as required.