2018 / ECLIPSE CROSS / EC - Workshop Manual
23 -AUTOMATIC TRANSMISSION > 23A-CVT > TROUBLESHOOTING<CVT><CVT> > DIAGNOSIS CODE PROCEDURES > CODE No. P0713 CVT FLUID TEMPERATURE SENSOR MALFUNCTION
Code No. P0713: Malfunction of CVT Fluid Temperature Sensor (high input)
 
 
 
 
DIAGNOSTIC FUNCTION
CVT-ECU conducts fault detection by monitoring the terminal voltage of the CVT fluid temperature sensor.
 
 
JUDGEMENT CRITERIA
The CVT-ECU detects the fluid temperature -40°C or less for 5 seconds when the vehicle speed is 10km/h or more.
 
 
PROBABLE CAUSES
  • Malfunction of CVT fluid temperature sensor
  • Damaged wiring harness and connectors
  • Malfunction of CVT-ECU
 
 
DIAGNOSIS PROCEDURE
STEP 1. Check for open circuit in SPWR and SGND line between the CVT assembly connector and the CVT-ECU connector
Is the check result normal?
Go to Step 2.
Repair the connector(s) or the wiring harness.
 
STEP 2. Voltage measurement at CVT-ECU connector (SPWR terminal)
(1) Connect the CVT assembly connector and the CVT-ECU connector.
(2) Turn the ignition switch to the "LOCK" (OFF) position.
(3) Measure the CVT-ECU connector side by backprobing.
(4) Measure the voltage between the CVT-ECU connector SPWR terminal and body earth.
OK: 0 V
Is the check result normal?
Go to Step 3.
Repair the connector(s) or the wiring harness.
 
STEP 3. CVT fluid temperature sensor check
Refer to .
Is the check result normal?
Go to Step 4.
Replace the CVT fluid temperature sensor (valve body harness) (Refer to ).
 
STEP 4. Symptom recheck after erasing diagnosis code
Is the diagnosis code set?
Replace the CVT-ECU.
Intermittent malfunction (Refer to GROUP 00 - How to Cope with Intermittent Malfunction ).