Code No. C2101 Power Supply High Voltage
| caution | - If there is any problem in the CAN bus lines, an incorrect diagnosis code may be set. Prior to this diagnosis, diagnose the CAN bus lines (Refer to GROUP 54C - CAN Bus Diagnostics Table
). - Whenever ECU is replaced, ensure that the CAN bus lines are normal.
|
OPERATION
The ASC-ECU is energised by the valve power supply circuit (+BV terminal). When the power is supplied from the ignition switch (IG1) to the IG1 relay in ETACS-ECU, IG1 relay is turned on. At this time, the valve power supply circuit (IG1 terminal) energises the ASC-ECU.
DIAGNOSIS CODE SET CONDITIONS
This diagnosis code is set when the ASC-ECU power supply voltage is more than 18.0 ± 1.0 V.
PROBABLE CAUSES
- Battery failure
- ASC-ECU malfunction
- Charging system failed
DIAGNOSIS PROCEDURE
STEP 1. M.U.T.-IIISE CAN bus diagnosis
STEP 2. Diagnosis code recheck after resetting CAN bus lines
Is diagnosis code No. C2101 set?
Go to Step 3.
This diagnosis is complete.
STEP 4. Charging system check
STEP 5. Check whether the diagnosis code is set again.