STEP 1. M.U.T.-IIISE diagnosis code
STEP 2. M.U.T.-IIISE other system diagnosis code
STEP 3. M.U.T.-IIISE actuator test
STEP 4. Resistance measurement at keyless operation buzzer connector (earth line)
(1) Disconnect the connector, and measure at the wiring harness side.
(2) Measure the resistance between the keyless operation buzzer connector (earth line) and body earth.OK: Continuity exists (2 Ω or less)
Is the check result normal?
Go to Step 6.
Go to Step 5.
STEP 5. Check of open circuit in earth line between the keyless operation buzzer connector and the body earth.
STEP 6. Check of short to power supply, short to earth or open circuit in DRVB line between the keyless operation buzzer connector and the KOS&OSS-ECU connector terminal.
Is the check result normal?
Go to Step 7.
Repair the wiring harness.
STEP 7. Check of the troubles