2018 / ECLIPSE CROSS / EC - Workshop Manual
54 -CHASSIS ELECTRICAL > 54A-CHASSIS ELECTRICAL > COMBINATION METER > SYMPTOM PROCEDURES > THE SPEEDOMETER DOES NOT WORK (BUT THE OTHER METERS WORK).
Inspection Procedure 5: The speedometer does not work (the other meters work).
 
 
cautionBefore replacing the combination meter, be sure to check that the power supply circuit, earth circuit, and communication circuit are normal.
 
 
COMMENTS ON TROUBLE SYMPTOM
If only the speedometer does not operate, the ASC system and combination meter may have a problem.
 
 
PROBABLE CAUSES
  • Malfunction of ASC-ECU
  • Damaged harness wires and connectors
  • Malfunction of combination meter
 
 
DIAGNOSIS PROCEDURE
STEP 1. M.U.T.-IIISE CAN bus diagnostics
Use the M.U.T.-IIISE to diagnose the CAN bus lines.
Is the check result normal?
Go to Step 2.
Repair the CAN bus line (Refer to GROUP 54C - Troubleshooting ).
 
STEP 2. M.U.T.-IIISE diagnosis code
Check if diagnosis code is set in the combination meter.
Is the diagnosis code set?
Troubleshoot the combination meter. Refer to .
Go to Step 3.
 
STEP 3. M.U.T.-IIISE other system diagnosis code
Check if diagnosis code is set in the ASC.
Is the diagnosis code set?
Troubleshoot the ASC. Refer to GROUP 35C - Troubleshooting .
Go to Step 4.
 
STEP 4. M.U.T.-IIISE other system data list
Check the vehicle speed signal data list of ASC system.
Item No.24: Vehicle speed (Refer to GROUP 35C, Data list reference table .)
Is the check result normal?
Go to Step 5.
Troubleshoot the ASC. Refer to GROUP 35C - Troubleshooting .
 
STEP 5. M.U.T.-IIISE actuator test
  • Item No.1: Speedometer (Refer to ).
Is the check result normal?
Go to Step 6.
Replace combination meter.
 
STEP 6. M.U.T.-IIISE Special Function
Using M.U.T.-IIISE, select "Test" from the special function of the combination meter. Execute the following item to check the pointer.
  • Item No.1: Pointer (AUTO) (Refer to ).
Is the check result normal?
Go to Step 7.
Replace the combination meter.
 
STEP 7. Retest the system.
Check that combination meter illumination function should work normally.
Is the check result normal?
The procedure is complete. (If no malfunctions are found in all steps, an intermittent malfunction is suspected. Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunction ).
Replace the combination meter.