54 -CHASSIS ELECTRICAL > 54A-CHASSIS ELECTRICAL > ETACS > INPUT SIGNAL PROCEDURES > THE SIGNAL FROM THE DOOR LOCK SWITCH (INCORPORATED WITH THE POWER WINDOW MAIN SWITCH) IS NOT RECEIVED.
Inspection Procedure 21: The door lock switch (incorporated with the power window main switch) signal is not received.
caution
Before replacing the ECU, ensure that the power supply circuit, the earth circuit and the communication circuit are normal.
COMMENTS ON TROUBLE SYMPTOM
The door lock switch input signal is used for the operation judgement of the functions below. If the signal is abnormal, these functions will not work normally.
Central door locking
PROBABLE CAUSES
Malfunction of the door lock switch (built in the power window main switch)
Damaged harness wires and connectors
Malfunction of the ETACS-ECU
DIAGNOSIS PROCEDURE
STEP 1. Door lock switch check.
Refer to GROUP 42A - Door, Door Handle and Latch, Inspection .
Is the check result normal?
Go to Step 2.
Replace the power window main switch (Refer to GROUP 52A - Trim, Door Trim ).
STEP 2. Resistance measurement at power window main switch (door lock switch) connector (earth terminal).
(1) Disconnect the connector, and measure at the wiring harness side.
(2) Measure the resistance between the power window main switch (door lock switch) connector (earth terminal) and body earth.
OK: Continuity exists (2 Ω or less)
Is the check result normal?
Go to Step 4.
Go to Step 3.
STEP 3. Check of open circuit in earth line between power window main switch (door lock switch) connector and body earth.
Is the check result normal?
Intermittent malfunction is suspected (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunction ).
Repair the connector(s) or wiring harness.
STEP 4. Check of short to power supply, short to earth, and open circuit in D-LS, D-US line between ETACS-ECU connector and power window main switch (door lock switch) connector.
Is the check result normal?
Go to Step 5.
Repair the connector(s) or wiring harness.
STEP 5. M.U.T.-IIISE data list.
Change the input signals from the door lock switch.
Item No.
Item name
Normal condition
100
Central door lock switch
OFF to ON (Only when switch is operated)
101
Central door unlock switch
OFF to ON (Only when switch is operated)
OK: Normal condition is displayed.
Is the check result normal?
The trouble can be an intermittent malfunction (Refer to GROUP 00 - How to use Troubleshooting/inspection Service Points - How to Cope with Intermittent Malfunction ).