STEP 1. Resistance measurement at the security alarm siren connector
(1) Disconnect the connector, and measure at the wiring harness side.
(2) Measure the resistance between the security alarm siren connector (earth terminal) and the body earth.OK: Continuity exists (2 Ω or less)
Is the check result normal?
Go to Step 3.
Go to Step 2.
STEP 2. Check of open circuit in body earth line between security alarm siren connector (earth terminal) and the body earth.
STEP 3. Voltage measurement at the security alarm siren connector.
(1) Disconnect the connector, and measure at the wiring harness side.
(2) Measure the voltage between the security alarm siren connector (power supply terminal) and the body earth.OK: System voltage
Is the check result normal?
Go to Step 5.
Go to Step 4.
STEP 4. Check of short to power supply, short to earth, and open circuit in BUP4 line between ETACS-ECU connector and security alarm siren connector.
STEP 5. Check of open circuit in LITI line between ETACS-ECU connector and security alarm siren connector.
Is the check result normal?
Go to Step 6.
Repair the connector(s) or wiring harness.
STEP 6. Replace the security alarm siren temporarily, and check whether the diagnosis code is set.
Check again if the diagnosis code is set in the ETACS-ECU.(1) Erase the diagnosis code.
(2) Turn the ignition switch from the "LOCK" (OFF) position to the "ON" position.
(3) Check if diagnosis code is set.
Is the diagnosis code set?
Replace the security alarm siren (Refer to GROUP 54A - Security Alarm Siren Removal And Installation
).
A poor connection, open circuit, or other intermittent malfunctions in the LIN bus lines between the security alarm sensor and the ETACS-ECU (Refer to GROUP 00 - How to Cope with Intermittent Malfunction
).