STEP 1. M.U.T.-IIISE other system data list.
Using the ETACS-ECU data list (Refer to
), check the LDW switch signal.- When the LDW switch is pressed.
| | | Item No. | Item name | Normal condition | | 109 | LDW switch | ON |
|
- When the LDW switch is not pressed.
| | | Item No. | Item name | Normal condition | | 109 | LDW switch | OFF |
|
OK: Normal condition is displayed.
Is the check result normal?
Go to Step 2.NO : Go to Step 4
.
STEP 2. M.U.T.-IIISE data list.
STEP 3. Retest the system.
STEP 4. Check of short to earth, and open circuit in LDWS line between ETACS-ECU connector and LDW switch connector.
Is the check result normal?
Go to Step 5.
Repair the connector(s) or wiring harness.
STEP 5. Check of open circuit in earth line between LDW switch connector and body earth.
Is the check result normal?
Go to Step 6.
Repair the connector(s) or wiring harness.
STEP 6. Check the LDW switch.
STEP 7. M.U.T.-IIISE other system data list.