Suzuki Vitara (LY) 2016-2017 · Service Manual D16AA · Diagnostic Information and Procedures

Fuel Flow Actuator Operation Check

Precautions: General safety (00)

Circuit Diagram
img
[A]: ECM connector (View: [a]) B1: Fuel pressure sensor power supply circuit 1. ECM
A1: Fuel flow actuator power supply circuit B2: Fuel pressure sensor signal circuit 2. Fuel flow actuator
A2: Fuel flow actuator drive circuit B3: Fuel pressure sensor ground circuit 3. Fuel pressure sensor
Troubleshooting
Step Action Yes No
1
Fuel flow actuator power supply circuit and drive circuit check
1)When ignition is “OFF”, disconnect “D01” connector from ECM and fuel flow actuator connector.
2)Check for proper terminal connection to “D01” connector and fuel flow actuator connector.
3)If connections are OK, check the following points.
•Resistance of “A1” and “A2” circuits: less than 1 Ω
•Resistance between “A1” circuit and ground: infinity
•Resistance between “A2” circuit and ground: infinity
•Resistance between “A1” circuit terminal and other terminal at fuel flow actuator connector: infinity
•Voltage of “A1” and “A2” circuits: approx. 0 V (When ignition is “ON”)
Is check result OK?
Go to Step 2.
Repair defective wire harness.
2
Fuel flow actuator check
1)When ignition is “OFF”, connect “D01” connector to ECM and fuel flow actuator connector.
2)Check fuel flow actuator. icon 
Is check result OK?
Check low-pressure fuel supply circuit and high-pressure fuel supply circuit.
•Low-pressure fuel supply circuit: icon 
•High-pressure fuel supply circuit: icon 
Replace high pressure pump. icon