Glow Plug Control Module Removal and Installation
Precautions: General safety (00)
Removal
1)Disconnect negative (–) cable at battery.
2)Remove wiring harness clamps (1) from bracket of glow plug control module.
4)Remove glow plug control module from bracket.
Installation
Reverse removal procedure noting the following point.
•Connect connectors glow plug control module securely.