Suzuki Vitara (LY) 2016-2017 · Service Manual D16AA ยท Repair Instructions

Air Cleaner Filter Removal and Installation

Precautions: General safety (00)

Removal
1)Remove air cleaner suction No.2 pipe (1).
2)Remove MAF sensor with IAT sensor-1 harness from air cleaner lower case clamp (2).
3)Open air cleaner upper case (3) by unhooking its clamps (4).
img
4)Remove air cleaner filter from air cleaner lower case.
Installation
Reverse removal procedure.