Cool air does not come out or insufficient cooling (compressor in normal operation)
Precautions: Precautions for Diagnosing Trouble · General safety (00)
| Condition | Possible Cause | Action |
|---|---|---|
|
Cool air does not come out or insufficient cooling (compressor in normal operation)
|
Faulty blower motor
|
|
|
Faulty temperature control actuator
|
||
|
Air leakage from HVAC unit or air duct
|
Repair HVAC unit or air duct.
|
|
|
Loose or broken compressor drive belt (petrol model)
|
||
|
Loose or broken generator drive belt (diesel model)
|
||
|
Faulty magnet clutch (petrol model)
|
||
|
Faulty compressor pulley (diesel model)
|
||
|
Faulty compressor ON/OFF valve (diesel model)
|
||
|
Faulty compressor
|
Check compressor.
|
|
|
Faulty expansion valve
|
||
|
Clogged desiccant
|
Check desiccant and cap.
|
|
|
Faulty heater and ventilation system
|
Check HVAC unit.
|
|
|
Insufficient or excessive charge of refrigerant
|
Check amount of refrigerant and system for leakage.
|
|
|
Excessive compressor oil in A/C system
|
Drain excessive compressor oil from A/C system circuit and compressor.
|
|
|
Clogged condenser
|
||
|
Clogged or frosted evaporator
|
Check evaporator and evaporator temperature sensor.
|
|
|
Faulty evaporator temperature sensor
|
||
|
Air in A/C system
|