DTC P0441 Evaporative Emission Control System Incorrect Purge Flow |
| DTC No. | Monitoring Items | Malfunction Detection Conditions | Trouble Areas | Detection Timing | Detection Logic |
| P0441 | Purge Vacuum Switching Valve (VSV) stuck open | Leak detection pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure measured. 0.02 inch leak criterion measured at start and at end of leak check. If stabilized pressure higher than [second 0.02 inch leak criterion x 0.2], ECM determines that purge VSV stuck open. |
| While ignition switch OFF | 2 trip |
| P0441 | Purge VSV stuck closed | After EVAP leak check performed, purge VSV turned ON (open), and atmospheric air introduced into EVAP system. 0.02 inch leak criterion measured at start and at end of leak check. If pressure does not return to near atmospheric pressure, ECM determines that purge VSV stuck closed. |
| While ignition switch OFF | 2 trip |
| P0441 | Purge flow | While engine running, following conditions are met:
|
| While engine running | 2 trip |
| Sequence | Operations | Descriptions | Duration |
| - | ECM activation | Activated by soak timer 5, 7 or 9.5 hours after ignition switch OFF. | - |
| A | Atmospheric pressure measurement | Vent valve turned OFF (vent) and EVAP system pressure measured by ECM in order to register atmospheric pressure. If pressure in EVAP system not between 70 kPa and 110 kPa (525 mmHg and 825 mmHg), ECM cancels EVAP system monitor. | 10 seconds |
| B | First 0.02 inch leak criterion (reference pressure) measurement | In order to determine 0.02 inch leak criterion, leak detection pump creates negative pressure (vacuum) through reference orifice and then ECM checks if leak detection pump and vent valve operate normally. | 60 seconds |
| C | EVAP system pressure measurement | Vent valve turned ON (closed) to shut EVAP system. Negative pressure (vacuum) created in EVAP system, and EVAP system pressure then measured. Write down measured value as it will be used in leak check. If EVAP pressure does not stabilize within 900 seconds, ECM cancels EVAP system monitor. | 900 seconds* |
| D | Purge VSV monitor | Purge VSV opened and then EVAP system pressure measured by ECM. Large increase indicates normal. | 10 seconds |
| E | Second 0.02 inch leak criterion (reference pressure) measurement | After second 0.02 inch leak criterion measurement, leak check performed by comparing first and second 0.02 inch leak criterion. If stabilized system pressure higher than second 0.02 inch leak criterion, ECM determines that EVAP system leaking. | 60 seconds |
| F | Final check | Atmospheric pressure measured and then monitoring result recorded by ECM. | - |



![]() |
| Related DTCs | P0441: Purge VSV stuck open P0441: Purge VSV stuck closed P0441: Purge flow |
| Required sensors/Components | Purge VSV, Pump module |
| Frequency of operation | Once per driving cycle |
| Duration | Purge VSV stuck open and closed: Within 15 min. (varies with amount of fuel in tank) Purge flow: Within 10 min. |
| MIL operation | 2 driving cycles |
| Sequence operation | None |
| The monitor will run whenever this DTC is not present | P0011 (VVT System 1 - Advance) P0012 (VVT System 1 - Retard) P0021 (VVT System 2 - Advance) P0022 (VVT System 2 - Retard) P0100 - P0103 (MAF sensor) P0110 - P0113 (IAT sensor) P0115 - P0118 (ECT sensor) P0120 - P0223, P2135 (TP sensor) P0125 (Insufficient ECT for closed loop) P0171, P0172 (Fuel system) P0300, P0308 (Misfire) P0335 (CKP sensor) P0351 - P0358 (Ignitor) P0450 - P0453 (EVAP pressure sensor) P0500 (VSS) |
| Atmospheric pressure | 70 to 110 kPa (525 to 825 mmHg) |
| Battery voltage | 10.5 V or more |
| Vehicle speed | Less than 2.5 mph (4 km/h) |
| Ignition switch | OFF |
| Time after key off | 5 or 7 or 9.5 hours |
| EVAP pressure malfunction (P0450, P0452, P0453) | Not detected |
| EVAP canister purge valve | Not operated by scan tool |
| EVAP canister vent valve | Not operated by scan tool |
| EVAP leak detection pump | Not operated by scan tool |
| Both of the following conditions are met before key off | Condition 1 and 2 |
| 1. Duration that vehicle has been driven | 5 minutes or more |
| 2. EVAP purge operation | Performed |
| ECT | 4.4 to 35°C (40 to 95°F) |
| IAT | 4.4 to 35°C (40 to 95°F) |
| Next sequence is run if the following condition is set | - |
| Atmospheric pressure | Within 0.3 kPa (2.25 mmHg) in 1 second |
| Next sequence is run if the following conditions are set | - |
| EVAP pressure just after reference pressure measurement start | -1 kPa (-7.5 mmHg) or less |
| Reference pressure | -4.85 to -1.057 kPa (-36.38 to -7.93 mmHg) |
| Reference pressure | Saturated |
| Next sequence is run if the following condition is set | - |
| EVAP pressure change after vent valve is ON | 0.3 kPa (2.25 mmHg) or more |
| Next sequence is run if the following condition is set | - |
| EVAP pressure | Saturated within 15 minutes |
| Next sequence is run if the following condition is set | - |
| EVAP pressure change after purge valve is open | 0.3 kPa (2.25 mmHg) or more |
| Next sequence is run if the following conditions are set | - |
| EVAP pressure just after reference pressure | -1 kPa (-7.5 mmHg) or less |
| Reference pressure | -4.85 to -1.057 kPa (-36.38 to -7.93 mmHg) |
| Reference pressure | Saturated |
| Difference between the first reference pressure and the second reference pressure | Less than 0.7 kPa (5.25 mmHg) |
| Next sequence is run if the following condition is set | - |
| EVAP pressure when vacuum introduction is complete | Lower than second reference pressure |
| EVAP monitor is complete if the following condition is set | - |
| Atmospheric pressure difference between sequence 1 to 8 | Within 0.3 kPa (2.25 mmHg) |
| Engine | Running |
| ECT | 4.4°C (40°F) |
| IAT | 4.4°C (40°F) |
| EVAP pressure sensor | Not detected |
| EVAP canister purge valve | Not operated by scan tool |
| EVAP system check | Not operated by scan tool |
| Battery voltage | 10 V or more |
| Purge duty cycle | 8 % or more |
| EVAP pressure when vacuum introduction is complete | Higher than reference pressure x 0.2 |
| EVAP pressure change after EVAP canister purge valve is open | Less than 0.3 kPa (2.25 mmHg) |
| Both of the following conditions are met | Condition 1 or 2 |
| 1. EVAP pressure change when purge flow is started | Less than 0.1 kPa (0.75 mmHg) |
| 2. EVAP pressure change during purge flow when EVAP pressure switching valve is ON (closed) | Less than 0.5 kPa (3.75 mmHg) |