Home › ENGINE · 2UZ-FE › ENGINE CONTROL SYSTEM › SFI SYSTEM

DTC    P0351    Ignition Coil "A" Primary / Secondary Circuit

DTC    P0352    Ignition Coil "B" Primary / Secondary Circuit

DTC    P0353    Ignition Coil "C" Primary / Secondary Circuit

DTC    P0354    Ignition Coil "D" Primary / Secondary Circuit

DTC    P0355    Ignition Coil "E" Primary / Secondary Circuit

DTC    P0356    Ignition Coil "F" Primary / Secondary Circuit

DTC    P0357    Ignition Coil "G" Primary / Secondary Circuit

DTC    P0358    Ignition Coil "H" Primary / Secondary Circuit

for Preparation Click here


DESCRIPTION

HINT:
  1. These DTCs indicate a malfunction related to a primary circuit.
  2. If DTC P0351 is displayed, check No. 1 ignition coil circuit.
  3. If DTC P0352 is displayed, check No. 2 ignition coil circuit.
  4. If DTC P0353 is displayed, check No. 3 ignition coil circuit.
  5. If DTC P0354 is displayed, check No. 4 ignition coil circuit.
  6. If DTC P0355 is displayed, check No. 5 ignition coil circuit.
  7. If DTC P0356 is displayed, check No. 6 ignition coil circuit.
  8. If DTC P0357 is displayed, check No. 7 ignition coil circuit.
  9. If DTC P0358 is displayed, check No. 8 ignition coil circuit.

A Direct Ignition System (DIS) is used on this vehicle.
The DIS is a 1-cylinder ignition system which ignites one cylinder with one ignition coil. In the 1-cylinder ignition system, the one spark plug is connected to the end of the secondary winding. High voltage generated in the secondary winding is applied directly to the spark plug. The spark of the spark plug passes from the center electrode to the ground electrode.
The ECM determines the ignition timing and outputs the ignition signals (IGTs) for each cylinder. Using the IGTs, the ECM turns the power transistor inside the igniter on/off, which switches on/off current to the primary coil. When current to the primary coil is cut off, high voltage is generated in the secondary coil and this voltage is applied to the spark plugs to create sparks inside the cylinders. As the ECM cuts current to the primary coil, the igniter sends back ignition confirmation signals (IGFs) for each cylinder ignition to the ECM.

A117778E04


DTC No.
DTC Detection Condition
Trouble Area
P0351
P0352
P0353
P0354
P0355
P0356
P0357
P0358
No IGF signal to ECM while engine is running
  1. Ignition system
  2. Open or short in IGF or IGT circuit (1 to 8) between ignition coil with igniter and ECM
  3. No. 1 to No. 8 ignition coil (primary ignition)
  4. ECM

  1. A093278E13
  2. Reference: Inspect using an oscilloscope.
  3. While cranking or idling the engine, check the waveform between terminals IGT1 to IGT8 and E1, and IGF1 to IGF2 and E1 of the E6, E8 and E6 ECM connectors.
    Items
    Contents
    Terminals
    1. CH1: IGT1, IGT2, IGT3, IGT4, IGT5,
      IGT6, IGT7, IGT8 - E1
    2. CH2: IGF1, IGF2 - E1
    Equipment Settings
    2 V/DIV.
    20 msec./DIV.
    Condition
    While the engine is cranking or idling

MONITOR DESCRIPTION


A082388E19

If the ECM does not receive an IGF after sending an IGT, it interprets this as a fault in the igniter and sets a DTC.

MONITOR STRATEGY


Related DTCs
P0351: Igniter (cylinder 1) malfunction
P0352: Igniter (cylinder 2) malfunction
P0353: Igniter (cylinder 3) malfunction
P0354: Igniter (cylinder 4) malfunction
P0355: Igniter (cylinder 5) malfunction
P0356: Igniter (cylinder 6) malfunction
P0357: Igniter (cylinder 7) malfunction
P0358: Igniter (cylinder 8) malfunction
Required Sensors/Components (Main)
Igniter
Required Sensors/Components (Related)
Crankshaft position sensor
Frequency of Operation
Continuous
Duration
0.256 seconds + 4 sparks
MIL Operation
Immediate
Sequence of Operation
None

TYPICAL ENABLING CONDITIONS


The monitor will run whenever these DTCs are not present
None
Either of the following condition is met:
Condition 1 or 2
1. Starter
OFF
2. Engine RPM
1,500 rpm or less
Either of the following condition is met:
Condition (a) or (b)
(a) All of the following conditions are met:
-
Engine RPM
500 rpm or less
Battery voltage
6 V or more
(b) All of the following conditions are met:
-
Engine RPM
More than 500 rpm
Battery voltage
10 V or more
Number of sparks after CPU is reset
5 sparks or more

TYPICAL MALFUNCTION THRESHOLDS


Ignition signal fail count
More than 2 times
Ignition signal fail count
When IGF does not return despite sending IGT

COMPONENT OPERATING RANGE


IGF signal
Igniter outputs IGF signal when it receives IGT signal from ECM

WIRING DIAGRAM


A133712E01


INSPECTION PROCEDURE

HINT:
  1. Read freeze frame data using the intelligent tester. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was running or stopped, whether the engine was warmed up or not, whether the air/fuel ratio was lean or rich, as well as other data recorded at the time of a malfunction.
  2. If DTCs P0351, P0354, P0356 and P0357 are output simultaneously, IGF1 circuit may be open or short.
  3. If DTCs P0352, P0353, P0355 and P0358 are output simultaneously, IGF2 circuit may be open or short.

1.CHECK SPARK PLUG AND SPARK OF MISFIRING CYLINDER
  1. Check spark plug and spark of misfiring cylinder (Click here).



NG
Go to step 4
OK


2.CHECK HARNESS AND CONNECTOR (IGNITION COIL - ECM [IGF SIGNAL TERMINAL])


    A115891E02
  1. Disconnect the I1, I2, I3, I4, I5, I6, I7 or I8 ignition coil with igniter connectors.

  1. Disconnect the E4 ECM connector.

  1. Measure the resistance between the wire harness side connectors.

    Standard resistance:
    Tester Connection
    Specified Condition
    Ignition coil (I1-2) - IGF1 (E4-24)
    Below 1 Ω
    Ignition coil (I2-2) - IGF2 (E4-25)
    Ignition coil (I3-2) - IGF2 (E4-25)
    Ignition coil (I4-2) - IGF1 (E4-24)
    Ignition coil (I5-2) - IGF2 (E4-25)
    Ignition coil (I6-2) - IGF1 (E4-24)
    Ignition coil (I7-2) - IGF1 (E4-24)
    Ignition coil (I8-2) - IGF2 (E4-25)
    Ignition coil (I1-2) or IGF1 (E4-24) - Body ground
    10 kΩ or higher
    Ignition coil (I2-2) or IGF2 (E4-25) - Body ground
    Ignition coil (I3-2) or IGF2 (E4-25) - Body ground
    Ignition coil (I4-2) or IGF1 (E4-24) - Body ground
    Ignition coil (I5-2) or IGF2 (E4-25) - Body ground
    Ignition coil (I6-2) or IGF1 (E4-24) - Body ground
    Ignition coil (I7-2) or IGF1 (E4-24) - Body ground
    Ignition coil (I8-2) or IGF2 (E4-25) - Body ground

  1. Reconnect the ignition coil with igniter connectors.

  1. Reconnect the ECM connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


3.INSPECT ECM (IGF1 AND IGF2 VOLTAGE)


    E118245E24
  1. Disconnect the ignition coil with igniter connectors.

  1. Turn the ignition switch ON.

  1. Measure the voltage of the E4 and E6 ECM connectors.

    Standard voltage:
    Tester Connection
    Specified Condition
    IGF1 (E4-24) - E1 (E6-1)
    4.5 to 5.5 V
    IGF2 (E4-25) - E1 (E6-1)
    4.5 to 5.5 V

  1. Reconnect the ignition coil with igniter connectors.



NG
REPLACE ECM
OK

REPLACE IGNITION COIL WITH IGNITER 

4.CHECK HARNESS AND CONNECTOR (IGNITION COIL - ECM [IGT SIGNAL TERMINAL])


    A115891E03
  1. Disconnect the 11, 12, 13, 14, 15, 16, 17 or 18 ignition coil with igniter connectors.

  1. Disconnect the E8 ECM connector.

  1. Measure the resistance between the wire harness side connectors.

    Standard resistance:
    Tester Connection
    Specified Condition
    IGT (I1-3) - IGT1 (E4-8)
    Below 1 Ω
    IGT (I2-3) - IGT2 (E4-15)
    IGT (I3-3) - IGT3 (E4-11)
    IGT (I4-3) - IGT4 (E4-10)
    IGT (I5-3) - IGT5 (E4-13)
    IGT (I6-3) - IGT6 (E4-12)
    IGT (I7-3) - IGT7 (E4-14)
    IGT (I8-3) - IGT8 (E4-9)
    IGT (I1-3) or IGT1 (E4-8) - Body ground
    10 kΩ or higher
    IGT (I2-3) or IGT2 (E4-15) - Body ground
    IGT (I3-3) or IGT3 (E4-11) - Body ground
    IGT (I4-3) or IGT4 (E4-10) - Body ground
    IGT (I5-3) or IGT5 (E4-13) - Body ground
    IGT (I6-3) or IGT6 (E4-12) - Body ground
    IGT (I7-3) or IGT7 (E4-14) - Body ground
    IGT (I8-3) or IGT8 (E4-9) - Body ground

  1. Reconnect the ignition coil with igniter connectors.

  1. Reconnect the ECM connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


5.INSPECT ECM (IGT1, IGT2, IGT3, IGT4, IGT5, IGT6, IGT7 OR IGT8 VOLTAGE)


    A116425E08
  1. Measure the voltage of the E4 and E6 ECM connectors when the engine is cranked.

    Standard voltage:
    Tester Connection
    Specified Condition
    IGT1 (E4-8) - E1 (E6-1)
    0.1 to 4.5 V
    IGT2 (E4-15) - E1 (E6-1)
    IGT3 (E4-11) - E1 (E6-1)
    IGT4 (E4-10) - E1 (E6-1)
    IGT5 (E4-13) - E1 (E6-1)
    IGT6 (E4-12) - E1 (E6-1)
    IGT7 (E4-14) - E1 (E6-1)
    IGT8 (E4-9) - E1 (E6-1)



NG
REPLACE ECM
OK


6.INSPECT ECM (IGT1, IGT2, IGT3, IGT4, IGT5, IGT6, IGT7 OR IGT8 VOLTAGE)


    A116425E08
  1. Disconnect the I1, I2, I3, I4, I5, I6, I7 or I8 ignition coil with igniter connectors.

  1. Measure the voltage of the E4 and E6 ECM connectors when the engine is cranked.

    Standard voltage:
    Tester Connection
    Specified Condition
    IGT1 (E4-8) - E1 (E6-1)
    4.5 V or more
    IGT2 (E4-15) - E1 (E6-1)
    IGT3 (E4-11) - E1 (E6-1)
    IGT4 (E4-10) - E1 (E6-1)
    IGT5 (E4-13) - E1 (E6-1)
    IGT6 (E4-12) - E1 (E6-1)
    IGT7 (E4-14) - E1 (E6-1)
    IGT8 (E4-9) - E1 (E6-1)

  1. Reconnect the ignition coil with igniter connectors.



NG
REPLACE ECM
OK


7.INSPECT IGNITION COIL WITH IGNITER (POWER SOURCE)


    A054393E46
  1. Disconnect the I1, I2, I3, I4, I5, I6, I7 and I8 ignition coil with igniter connectors.

  1. Turn the ignition switch ON or START.

  1. Measure the voltage of the wire harness side connector and body ground.

    Standard voltage:
    Tester Connection
    Specified Condition
    +B (I1-1) - Body ground
    9 to 14 V
    +B (I2-1) - Body ground
    +B (I3-1) - Body ground
    +B (I4-1) - Body ground
    +B (I5-1) - Body ground
    +B (I6-1) - Body ground
    +B (I7-1) - Body ground
    +B (I8-1) - Body ground

  1. Reconnect the ignition coil connectors.



OK
REPLACE IGNITION COIL
NG


8.CHECK HARNESS AND CONNECTOR (IGNITION COIL - IGNITION SWITCH)


    A115892E01
  1. Disconnect the I1, I2, I3, I4, I5, I6, I7 or I8 ignition coil with igniter connectors.

  1. Disconnect the I18 ignition switch connector.

  1. Measure the resistance between the wire harness side connectors.

    Standard resistance:
    Tester Connection
    Specified Condition
    Ignition coil (I1-1) - IG2 (I18-6)
    Below 1 Ω
    Ignition coil (I2-1) - IG2 (I18-6)
    Ignition coil (I3-1) - IG2 (I18-6)
    Ignition coil (I4-1) - IG2 (I18-6)
    Ignition coil (I5-1) - IG2 (I18-6)
    Ignition coil (I6-1) - IG2 (I18-6)
    Ignition coil (I7-1) - IG2 (I18-6)
    Ignition coil (I8-1) - IG2 (I18-6)
    Ignition coil (I1-1) or IG2 (I18-6) - Body ground
    10 kΩ or higher
    Ignition coil (I2-1) or IG2 (I18-6) - Body ground
    Ignition coil (I3-1) or IG2 (I18-6) - Body ground
    Ignition coil (I4-1) or IG2 (I18-6) - Body ground
    Ignition coil (I5-1) or IG2 (I18-6) - Body ground
    Ignition coil (I6-1) or IG2 (I18-6) - Body ground
    Ignition coil (I7-1) or IG2 (I18-6) - Body ground
    Ignition coil (I8-1) or IG2 (I18-6) - Body ground

  1. Reconnect the ignition switch connector.

  1. Reconnect the ignition coil with igniter connectors.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE IGNITION COIL