DTCs
| Monitoring Items
| Malfunction Detection Conditions
| Trouble Areas
| Detection Timing
| Detection Logic
|
P043E
| Reference orifice clogged
| Leak detection pump creates negative pressure through reference orifice, and EVAP system pressure measured to determine leak criterion. 0.02 inch leak criterion measured at start and at end of leak check. If system pressure lower than -4.85 kPa (-36.38 mmHg)*, ECM determines that reference orifice has clogging malfunction.
| - Canister pump module
- Connector/wire harness
(Canister pump module - ECM)
- ECM
- Leakage from EVAP system
| While ignition switch OFF
| 2 trip
|
P043F
| Reference orifice high-flow
| Leak detection pump creates negative pressure through reference orifice, and EVAP system pressure measured to determine leak criterion. 0.02 inch leak criterion measured at start and at end of leak check. If system pressure higher than -1.06 kPa (-7.95 mmHg)*, ECM determines that reference orifice has high-flow malfunction.
| - Canister pump module
- Connector / Wire harness
(Canister pump module - ECM)
- ECM
- Leakage from EVAP system
| While ignition switch OFF
| 2 trip
|
Sequence
| Operations
| Descriptions
| Duration
|
-
| ECM activation
| Activated by soak timer 5, 7 or 9.5 hours after ignition switch OFF.
| -
|
A
| Atmospheric pressure measurement
| Vent valve turned OFF (vent) and EVAP system pressure measured by ECM in order to register atmospheric pressure. If pressure in EVAP system not between 70 kPa and 110 kPa (525 mmHg and 825 mmHg), ECM cancels EVAP system monitor.
| 10 seconds
|
B
| First 0.02 inch leak criterion (reference pressure) measurement
| In order to determine leak criterion, leak detection pump creates negative pressure (vacuum) through reference orifice and then ECM checks if leak detection pump and vent valve operate normally.
| 60 seconds
|
C
| EVAP system pressure measurement
| Vent valve turned ON (closed) to shut EVAP system. Negative pressure (vacuum) created in EVAP system, and EVAP system pressure then measured. Write down measured value as it will be used in leak check. If EVAP pressure does not stabilize within 900 seconds, ECM cancels EVAP system monitor.
| 900 seconds*
|
D
| Purge VSV monitor
| Purge VSV opened and then EVAP system pressure measured by ECM. Large increase indicates normal.
| 10 seconds
|
E
| Second 0.02 inch leak criterion (reference pressure) measurement
| After second 0.02 inch leak criterion measurement, leak check performed by comparing first and second 0.02 inch leak criterion. If stabilized system pressure higher than second 0.02 inch leak criterion, ECM determines that EVAP system leaking.
| 60 seconds
|
F
| Final check
| Atmospheric pressure measured and then monitoring result recorded by ECM.
| -
|
The monitor will run whenever these DTCs are not present
| None
|
Atmospheric pressure
| 70 to 110 kPa (525 to 825 mmHg)
|
Battery voltage
| 10.5 V or higher
|
Vehicle speed
| Less than 2.5 mph (4 km/h)
|
Ignition switch
| OFF
|
Time after key off
| 5 or 7 or 9.5 hours
|
EVAP pressure malfunction (P0450, P0452, P0453)
| Not detected
|
EVAP canister purge valve
| Not operated by scan tool
|
EVAP canister vent valve
| Not operated by scan tool
|
EVAP leak detection pump
| Not operated by scan tool
|
Both of the following conditions are met before key off
| Condition 1 and 2
|
1. Duration that vehicle has been driven
| 5 minutes or more
|
2. EVAP purge operation
| Performed
|
ECT
| 4.4 to 35°C (40 to 95°F)
|
IAT
| 4.4 to 35°C (40 to 95°F)
|